21por van de Bank, Bart L., Orzada, Stephan, Smits, Frits, Lagemaat, Miriam W., Rodgers, Christopher T., Bitz, Andreas K., Scheenen, Tom W. J.“…It consists of an eight‐channel (1)H transmit–receive head coil with multi‐transmit capabilities, and an insertable, actively detunable (31)P birdcage (transmit–receive and transmit only), which can be combined with a seven‐channel receive‐only (31)P array. …”
Publicado 2015
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
22por Stijnman, Peter R. S., Stefano Mandija, Fuchs, Patrick S., van den Berg, Cornelis A. T., Remis, Rob F.“…This allows for CSI‐EPT to fully exploit the benefits of the higher static magnetic field strengths with a standard quadrature birdcage coil setup.…”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
23por Santoro, Davide, Winter, Lukas, Müller, Alexander, Vogt, Julia, Renz, Wolfgang, Özerdem, Celal, Grässl, Andreas, Tkachenko, Valeriy, Schulz-Menger, Jeanette, Niendorf, Thoralf“…For this purpose, RF power deposition that exceeds the clinical limits was induced by a dedicated birdcage coil. Fiber optic probes and MR thermometry were applied for temperature monitoring using agarose phantoms containing copper tubes or coronary stents. …”
Publicado 2012
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
24por Brink, Wyger M., Yousefi, Sahar, Bhatnagar, Prernna, Remis, Rob F., Staring, Marius, Webb, Andrew G.“…The segmentation accuracy was evaluated through local SAR simulations in a quadrature birdcage as well as a PTx coil model. RESULTS: The network‐generated segmentations reached Dice coefficients of 86.7% ± 6.7% (mean ± SD) and showed to successfully address the severe intensity bias and contrast variations typical to 7T. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
25por McElcheran, C. E., Golestanirad, L., Iacono, M. I., Wei, P.-S., Yang, B., Anderson, K. J. T., Bonmassar, G., Graham, S. J.“…Electromagnetic simulations were performed using 4- and 8-element pTx coils compared with a standard birdcage coil excitation using patient models and lead trajectories obtained by segmentation of computed tomography data. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
26por van Houtum, Q., Welting, D., Gosselink, W.J.M., Klomp, D.W.J., Arteaga de Castro, C.S., van der Kemp, W.J.M.“…Conventional surface coils require high energy adiabatic RF pulses to achieve flip angle homogeneity, leading to high specific absorption rates (SARs), and occupy space within the MRI bore. A birdcage coil behind the bore cover can potentially reduce the SAR constraints massively by use of conventional amplitude modulated pulses without sacrificing patient space. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
27por Affram, Kevin, Smith, Taylor, Helsper, Shannon, Rosenberg, Jens T., Han, Bo, Trevino, Jose, Agyare, Edward“…Using a 33-mm inner diameter birdcage coil, T(1) maps were acquired, and signal to noise ratio (SNR) measured for 2 h. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
28por van Houtum, Quincy (.Q.)., Mohamed Hoesein, Firdaus (.F.A.A.)., Verhoeff, Joost (.J.J.C.)., van Rossum, Peter (.P.S.N.)., van Lindert, Anne (.A.S.R.)., van der Velden, Tijl (.T.A.)., van der Kemp, Wybe (.W.J.M.)., Klomp, Dennis (.D.W.J.)., Arteaga de Castro, Catalina (.C.S.).“…Here, we investigate the feasibility of 3D (31)P MRSI at 7 T in lung carcinoma patients using an integrated (31)P birdcage body coil in combination with either a dual‐coil or a 16‐channel receiver. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
29por Ellenor, Christopher W, Stang, Pascal P, Etezadi-Amoli, Maryam, Pauly, John M, Scott, Greig C“…THEORY: The behavior of coupled oscillators is reviewed, and the resulting, observable impedance changes are discussed. METHODS: A birdcage coil is loaded with a static head phantom and a wire phantom with a wire close to its resonant length, the shape, position, and orientation of which can be changed. …”
Publicado 2015
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
30por Waiczies, Helmar, Lepore, Stefano, Drechsler, Susanne, Qadri, Fatimunnisa, Purfürst, Bettina, Sydow, Karl, Dathe, Margitta, Kühne, André, Lindel, Tomasz, Hoffmann, Werner, Pohlmann, Andreas, Niendorf, Thoralf, Waiczies, Sonia“…We constructed a very small dual-tunable radio frequency (RF) birdcage probe tailored for (19)F (fluorine) and (1)H (proton) MR mouse neuroimaging. …”
Publicado 2013
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
31“…This setup makes use of a high thermal-stability Birdcage-coil for measuring the quantitative moisture content at high-temperatures, while also utilizing a mini-coil for calibrating transverse relaxation changes, as a function of temperature and hydration state, taking place in the sample throughout a drying experiment. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
32por Baio, Gabriella, Fabbi, Marina, Cilli, Michele, Rosa, Francesca, Boccardo, Simona, Valdora, Francesca, Salvi, Sandra, Basso, Luca, Emionite, Laura, Gianolio, Eliana, Aime, Silvio, Neumaier, Carlo Emanuele“…Mice were studied on a clinical 3T scanner by using a prototype birdcage coil before and after intravenous injection of MnCl(2). …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
33“…Spontaneous and controlled chewing with sugar-free gum was used as the main task in a 3-Tesla fMRI unit with a 32-channel birdcage coil. Our study popu-lation comprised 32 healthy volunteers. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
34“…In general, the reference or standard radiofrequency (RF) coils for these performance assessments of 1.5 to 7.0 T MRI systems have been low-pass-type birdcage (LP-BC) RF coils. However, LP-BC RF coils are inappropriate for use as reference RF coils because of their relatively lower magnetic field (B(1)-field) sensitivity than other types of BC RF coils, especially in ultrahigh-field (UHF) MRI systems above 3.0 T. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
35“…We developed an array with whole-volume coverage of the calf and a phosphorus signal-to-noise ratio of more than double that of a birdcage coil in the gastrocnemius muscles. This enabled the local assessment of phosphocreatine recovery kinetics following a plantar flexion exercise using an efficient sampling scheme with a 6 s temporal resolution. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
36“…CASE PRESENTATION: A 61-years-old man with the main complaint of sudden shortness of breath after lifting a birdcage. The complaint worsened, and it was accompanied by nausea, sweating, and decreased vital signs. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
37por Navarro de Lara, Lucia I., Windischberger, Christian, Kuehne, Andre, Woletz, Michael, Sieg, Jürgen, Bestmann, Sven, Weiskopf, Nikolaus, Strasser, Bernhard, Moser, Ewald, Laistler, Elmar“…METHODS: The state‐of‐the‐art setup for concurrent TMS/fMRI is to use a large birdcage head coil, with the TMS between the subject's head and the MR coil. …”
Publicado 2014
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
38por Tricot, Benoit, Descoteaux, Maxime, Dumont, Matthieu, Chagnon, Frederic, Tremblay, Luc, Carpentier, André, Lesur, Olivier, Lepage, Martin, Lalande, Alain“…BACKGROUND: We investigate the use of different denoising filters on low signal-to-noise ratio cardiac images of the rat heart acquired with a birdcage volume coil at 7T. Accuracy and variability of cardiac function parameters were measured from manual segmentation of rat heart images with and without filtering. …”
Publicado 2017
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
39“…We present the validation for two types of resonators with very different filling factors: a solenoid and a so-called birdcage coil. The latter is a volume coil, which is generally used in magnetic resonance imaging (MRI) under in vivo condition. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
40“…As a result, the cross flap becomes a birdcage-like tower. The rolled auricular cartilage is placed into the pocket. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto