Mostrando 41 - 54 Resultados de 54 Para Buscar '"The Birdcage"', tiempo de consulta: 0.07s Limitar resultados
  1. 41
    “…METHODS: The 8Tx‐dipoles/32Rx‐loops coil array was characterized by the SNR, g‐factors, noise correlation matrix, accelerated image quality, and [Formula: see text] maps, and compared with a commercial 1Tx‐birdcage/32Rx‐loops array. Simulated and measured [Formula: see text] maps were shown for the 8Tx‐dipoles/32Rx‐loops coil array and compared with the 8Tx/Rx dipole array. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  2. 42
    “…METHODS: Pregnant models in the 3rd, 7th, and 9th months of gestation were used for simulations in a birdcage coil at 3T. Dielectric pads were optimized regions of interest (ROI) using previously developed methods for [Formula: see text] efficiency and homogeneity and were designed for 2 ROIs: the entire fetus and the brain of the fetus. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  3. 43
    por Bonmassar, Giorgio, Serano, Peter
    Publicado 2020
    “…The heating was induced by RF fields in a 1.5 T MRI head birdcage coil (often used for imaging patients with implants) at 64 MHz, and normalized results to 3.2 W/kg whole head average SAR. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  4. 44
    “…In this study, we investigate, for a 32‐channel receiver head array at 7 T, if transmitter detuning of a quadrature birdcage or of an eight‐channel transmit coil can be omitted without substantially sacrificing signal‐to‐noise ratio (SNR). …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  5. 45
    “…Given the same or similar coil settings, the computational human model generates meaningful results for SAR, B1 field, and temperature rise when used in conjunction with the 1.5 T birdcage MRI coils or at higher frequencies corresponding to 3 T MRI. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  6. 46
    “…Methods: A numerical model of an RF birdcage body coil and an anatomically realistic virtual patient with a native spatial resolution of 1 mm(3) were used to simulate the in vivo electric field at 64 MHz (1.5 T MRI system). …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  7. 47
    “…The combined magnetic flux density (||B(1)||) distributions of four configurations of PA coils—4-, 8-, 12-, and 16-channel Rx-only mode under the local transmit (Tx) mode of birdcage coils—were evaluated using electromagnetic (EM) calculations. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  8. 48
    “…METHODS: Exposure from a 297‐MHz birdcage head transmit coil (CP mode single‐channel transmission) was simulated in several child models (ages 3–14, mass 13.9–50.4 kg) and one adult, using time‐domain electromagnetic and thermal solvers. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  9. 49
    “…Experiments were carried out with the exact same type of birdcage volume coil (except at 3 T, where a similar coil was used) to attempt at isolating the evolution of SNR with field strength alone. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  10. 50
    por Enoch, Stefan
    Publicado 2018
    “…Thanks to electromagnetic resonances and the Kerker effect, it is possible to redistribute and reshape the RF electromagnetic field in a birdcage antenna.</p> <p class="MsoBodyText">We will also show how these concepts could be used for other types of applications such as waterwave cloaking or seismic protection.…”
    Enlace del recurso
  11. 51
    “…RESULTS: From the finite-difference-time-domain (FDTD) electromagnetic field simulations with a human body model placed in a birdcage coil operating at 3 T, it was observed that the RF pulse calibration with iterative cost function minimization can give improvement of B(1) field uniformity as well as flip-angle calibration. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  12. 52
    “…Power deposition and temperature rise (ΔT) were evaluated with the model positioned in a whole-body birdcage RF coil in the presence of a tES setup. Multiphysics modeling at 3T (123.2 MHz) on unstructured meshes was based on RF circuit, 3D electromagnetic, and thermal co-simulations. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  13. 53
    “…To obtain 3D (31)P MRSI spectra with improved signal‐to‐noise ratio on clinical 3 T MR systems, we used a coil combination consisting of a dual‐tuned birdcage transmit coil and a (31)P eight‐channel phased‐array receive insert. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  14. 54
    “…RESULTS: We present a 72-year-old male with a history of JAK-2-positive polycythemia vera with secondary myelofibrosis, and concurrent multiple myeloma who presented with 3 weeks of chronic cough and 3 days of fever with severe bifrontal headache after remodeling a large birdcage in his backyard. The patient was on ruxolitinib, ixazomib, and weekly dexamethasone. …”
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
Herramientas de búsqueda: RSS