-
701por Hanna, Reem, Pawelczyk-Madalińska, Magdalena, Sălăgean, Tudor, Nap, Mircea Emil, Bordea, Ioana Roxana, Benedicenti, Stefano“…The laser protocols were as follows: λ2780 nm: power output—2 W, pulse width—60 μs, free running pulse (FRP), spot area—0.0016 cm(2), pulse repetition rate—25 pulses per second (s), 80 mJ/pulse, 90 s, λ940 nm: 1.2 W, continuous wave (CW) emission mode, 300 μm, 60 s; whereas the adjunctive λ940 nm induced-PBM parameters were as follows: power output—1.4 W, CW—120 s, single application, spot area—2.8 cm(2). …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
702por Macchi, Robin, Santuz, Alessandro, Hays, Arnaud, Vercruyssen, Fabrice, Arampatzis, Adamantios, Bar-Hen, Avner, Nicol, Caroline“…For each session, the mechanical force-velocity-power profile (i.e. theoretical maximal values of force ([Formula: see text] 0), velocity ([Formula: see text] 0), and power ([Formula: see text] max)) was computed. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
703por Al Shammari, Basim R.“…Ferric reducing antioxidant power (FRAP), 1,1-diphenyl-2-picrylhydrazyl (DPPH), and total antioxidant capacity (TAC) were used to assess the antioxidant effect of EOBD. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
704“…A significant boost in prognostic power (F1 score) from 0.33 (95% CI 0.31-0.35) to 0.45 (95% CI 0.45-0.45) was observed in external validation when variations in these subgroups were accounted in our model. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
705por Pernegger, H., Allport, P., Asensi Tortajada, I., Barbero, M., Barrillon, P., Berdalovic, I., Bespin, C., Bhat, S., Bortoletto, D., Breugnon, P., Buttar, C., Cardella, R., Dachs, F., Dao, V., Degerli, Y., Denizli, H., Dyndal, M., Flores Sanz de Acedo, L., Freeman, P., Gonella, L., Habib, A., Hemperek, T., Hirono, T., Hiti, B., Kugathasan, T., Mandić, I., Mikuž, M., Moustakas, K., Munker, M., Oyulmaz, K.Y., Pangaud, P., Piro, F., Riedler, P., Sandaker, H., Schioppa, E.J., Schwemling, P., Sharma, A., Simon Argemi, L., Solans Sanchez, C., Snoeys, W., Suligoj, T., Wang, T., Wermes, N.“…The sensors combine high granularity (pitch 36.4x 36.4μm$^2$), low detector capacitance (<5fF/pixel) of the charge collection electrode (3μm), low noise (ENC≈10e$^−$) and low power operation (1 μ W/pixel) with a fast signal response (25 ns bunch crossing). …”
Publicado 2021
Enlace del recurso
Enlace del recurso
-
706por Rousseaux, Floriane, Panda, Rajanikant, Toussaint, Clémence, Bicego, Aminata, Niimi, Masachika, Faymonville, Marie‐Elisabeth, Nyssen, Anne‐Sophie, Laureys, Steven, Gosseries, Olivia, Vanhaudenhuyse, Audrey“…VRH significantly decreased amplitudes of N100 and P200 ERP components, reduced EEG power between 1 and 5 Hz from 100 to 560 ms, and increased EEG power from 5 to 11 Hz from 340 to 800 ms. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
707por Hendlisz, Alain, Deleporte, Amélie, Vandeputte, Caroline, Charette, Nicolas, Paesmans, Marianne, Guiot, Thomas, Garcia, Camilo, Flamen, Patrick“…A target sample size of 105 evaluable patients (70 as derivation set and 35 as validation set), is considered as sufficient to validate an expected HR for OS of metabolic responders compared to metabolic non-responders significantly <1 (with 80% power and 1-sided 5% α in case of a true HR≤0.59 and a responders rate of 47%). …”
Publicado 2015
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
708“…Methods were compared on mean absolute error, bias, coverage and power over 1,000 datasets for each scenario. RESULTS: Overall, there was very little to separate multiple imputation methods which included the outcome in the imputation model. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
709“…Grip power was 15.3 kg and key-pinch power was 1.8 kg before operation. Preoperative waist flexion power was 20.9 kg. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
710por Peng, Xiong, Omasta, Travis J., Magliocca, Emanuele, Wang, Lianqin, Varcoe, John R., Mustain, William E.“…When paired with a radiation‐grafted ETFE powder ionomer, the N‐C‐CoO(x) AEMFC cathode was able to achieve extremely high peak power density (1.05 W cm(−2)) and mass transport limited current (3 A cm(−2)) for a precious metal free electrode. …”
Publicado 2018
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
711por Baldovin, Tatjana, Amoruso, Irene, Fonzo, Marco, Buja, Alessandra, Baldo, Vincenzo, Cocchio, Silvia, Bertoncello, Chiara“…Hospitalization data suggested an approximate WBE detection power of 1 COVID-19 case per 531 inhabitants. The possible role of WBE in COVID-19 environmental surveillance is strongly supported by our findings. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
712“…The sample size was determined taking the assumption of 95% CI, 85% power, 3:1 control to case ratio, the proportion of PLWHA-malaria coinfection of 22.7%, OR 2.73, and 10% non-response rate. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
713“…Source apportionment of PM(2.5) during the COVID-19 outbreak showed that industry and residential emissions were the dominant PM(2.5) contributors (32.7%–49.6% and 26.0%–44.5%, respectively) followed by agriculture (18.7%–24.0%), transportation (7.7%–15.5%), and power (4.1%–5.9%). In Beijing, industrial and residential contributions to PM(2.5) concentrations were lower (32.7%) and higher (44.5%), respectively, than in other cities (38.7%–49.6% for industry and 26.0%–36.2% for residential). …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
714por Zegeye, Betregiorgis, Adjei, Nicholas Kofi, Olorunsaiye, Comfort Z., Ahinkorah, Bright Opoku, Ameyaw, Edward Kwabena, Seidu, Abdul-Aziz, Yaya, Sanni“…Adherence to iron supplementation was found to be higher among pregnant married women who had decision-making power (AOR = 1.46, 95% CI; 1.16–1.83), secondary education (AOR = 1.45, 95% CI; 1.05–2.00) and antenatal care visit (AOR = 2.77, 95% CI; 2.19–3.51). …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
715por Joo, Min Gyu, Lim, Dae Hyeong, Park, Kyu-Kwan, Baek, Jiwon, Choi, Jong Min, Baac, Hyoung Won“…Thus, the reflection-boosted design not only enhanced measurement reliability but also significantly improved power consumption, i.e., by requiring only 36% and 30% power to drive the LED sources with λ(1) and λ(2), respectively, to produce the device performance of a non-reflective RPO reference. …”
Publicado 2023
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
716Publicado 1995“…Intrinsic buffering power (beta 1) decreased curvilinearly from approximately 25 mM at pHi = 6.4 to approximately 6.0 mM at pHi = 7.4. …”
Enlace del recurso
Enlace del recurso
Texto -
717por Mora-Rodríguez, Ricardo, Pallarés, Jesús García, López-Samanes, Álvaro, Ortega, Juan Fernando, Fernández-Elías, Valentín E.“…The neuromuscular test battery consisted in the measurement of bar displacement velocity during free-weight full-squat (SQ) and bench press (BP) exercises against loads that elicit maximum strength (75% 1RM load) and muscle power adaptations (1 m s(−1) load). Isometric maximum voluntary contraction (MVC(LEG)) and isometric electrically evoked strength of the right knee (EVOK(LEG)) were measured to identify caffeine's action mechanisms. …”
Publicado 2012
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
718por Raizada, Neeraj, Sachdeva, K. S., Sreenivas, Achuthan, Vadera, Bhavin, Gupta, R. S., Parmar, Malik, Kulsange, Shubhangi, Babre, Ameet, Thakur, Rahul, Gray, Christen, Ramachandran, Ranjani, Alavadi, Umesh, Ghedia, Mayank, Vollepore, Balasangameshwara, Dewan, Puneet, Boehme, Catharina, Paramsivan, C. N.“…Other reasons included power failure (1.1%), cartridge integrity/component failure (0.8%), device-computer communication error (0.5%), and temperature-related errors (0.08%). …”
Publicado 2014
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
719por Adams, Daniel L., Adams, Diane K., Stefansson, Steingrimur, Haudenschild, Christian, Martin, Stuart S., Charpentier, Monica, Chumsri, Saranya, Cristofanilli, Massimo, Tang, Cha-Mei, Alpaugh, R. Katherine“…METHODS: In this single-blind prospective pilot study, we tracked 36 patients with late-stage breast cancer over 24 months to compare overall survival between simple CTC enumeration and subtyping mitotic CTCs. A power analysis (1-β = 0. 9, α = 0.05) determined that a pilot size of 30 patients was sufficient to stratify this patient cohort; 36 in total were enrolled. …”
Publicado 2016
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
720por Kikkert, Lisette H. J. C., Vuillerme, Nicolas, van Campen, Jos P., Appels, Bregje A., Hortobágyi, Tibor, Lamoth, Claudine J.“…Outcomes related to speed, regularity, predictability, and stability of trunk accelerations revealed with the highest discriminative power (VIP > 1). A high proportion of healthy old adults (96 and 93% for single- and dual-task, respectively) was correctly classified based on the gait outcomes. …”
Publicado 2017
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto