61por Kapłonek, Wojciech, Nadolny, Krzysztof, Sutowska, Marzena, Mia, Mozammel, Pimenov, Danil Yurievich, Gupta, Munish Kumar“…The condition of grinding wheel active surface was analyzed using an advanced observation measurement system based on stylus/optical profilometry, as well as confocal and electron microscopy. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
62In-Situ Waviness Characterization of Metal Plates by a Lateral Shearing Interferometric Profilometer“…We describe a series of experiments over several samples of steel plates to validate the sensor and the processing method, and the results are in close agreement with those obtained with a contact stylus device. The sensor is an ideal candidate for on-line or in-machine fast automatic waviness assessment, reducing delays and costs in many metalworking processes.…”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
63por Carbonell, Carlos, Stylianou, Kyriakos C., Hernando, Jordi, Evangelio, Emi, Barnett, Sarah A., Nettikadan, Saju, Imaz, Inhar, Maspoch, Daniel“…Here we show that a femtolitre reaction can be realized on a surface by handling and mixing femtolitre volumes of reagents using a microfluidic stylus. This method, named microfluidic pen lithography, allows mixing reagents in isolated femtolitre droplets that can be used as reactors to conduct independent reactions and crystallization processes. …”
Publicado 2013
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
64por Pöller, Franziska, Salazar Bloise, Félix, Jakobi, Martin, Wang, Shengjia, Dong, Jie, Koch, Alexander W.“…In order to have reference roughness values of the samples, measurements with a stylus profilometer and with a confocal microscope are performed and compared.…”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
65por Shan, Dongri, Zhang, Chenglong, Zhang, Peng, Wang, Xiaofang, He, Dongmei, Xu, Yalu, Zhou, Maohui, Yu, Guoqi“…After the system camera calibration was completed, we took several pictures of the same measurement point with different poses to obtain the conversion matrix of the picture and subsequently used spherical fitting, the generalized inverse method of least squares, and the principle of position invariance in the pose domain range. The combined stylus tip center self-calibration method calculates the actual position of the light pen probe. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
66por Ruben, Bartali, Zhang, Gaixia, Xin, Tong, Giorgio, Speranza, Victor, Micheli, Gloria, Gottardi, Michele, Fedrizzi, Filippo, Pierini, Shuhui, Sun, Nadhira, Laidani, Ana C, Tavares“…The surface chemical composition, morphology and structure of the coatings were studied by X-ray photoemission spectroscopy (XPS), scanning electron microscopy (SEM), atomic force microscopy (AFM) and stylus profilometry. Moreover, a specific methodology based on the evolution of the water contact angle with time was used to evaluate the reactivity of the lead surface. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
67“…A comparison of the results of the backlit system depends on the values of surface roughness considered; while at larger values of roughness the offset increases, the results are compatible with the ones of the stylus at lower values of roughness. In fact, the error bands are superimposed by at least 58% based on the cases analyzed.…”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
68por Quinten, Michael“…The non-optical methods comprise tactile methods (stylus tip, AFM) as well as capacitive and inductive methods (capacitive sensors, eddy current sensors). …”
Publicado 2019
Enlace del recurso
Enlace del recurso
-
69“…The proposed methodology involves capturing a greyscale image of and profile measuring the surface topography in two perpendicular directions using a stylus method. A specially developed algorithm further identifies the best match between the measured profile segment and a row or column from the captured topography image by carrying out a signal correlation assessment based on an appropriate similarity metric. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
70“…Validation of layer optical properties and thicknesses were achieved with spectrophotometry and stylus profilometry, respectively. OCT B-scans were used to calculate CTFs and results were compared with convetional PSF measurements based on specular reflections. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
71“…Participants repeatedly tried to hit a circular target varying in size with a stylus movement under restricted feedback conditions. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
72por Alblalaihid, Khalid, Kinnell, Peter, Lawes, Simon, Desgaches, Dorian, Leach, Richard“…During switching, the stylus tip undergoes a displacement of approximately 18 µm, however, the control system is able ensure a consistent flexible mode tip deflection to within 12 nm in the vertical axis. …”
Publicado 2016
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
73“…From the results, an optical fiber micro-sphere with a two-dimensional (2D) diameter less than 80 µm, 2D roundness error less than 0.70 µm, 2D offset distance between the micro-sphere center and the fiber stylus central line less than 0.65 µm, and true sphericity of about 0.5 µm, is fabricated.…”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
74por Li, Ruijun, Chen, Chen, Fan, Kuangchao, Wang, Zhiwei, Liu, Fangfang, Huang, Qiangxian“…This study used an arc-discharge melting method to fabricate a micro monolithic tungsten ball tip on a tungsten stylus. The principles of arc discharge and surface tension phenomenon were introduced. …”
Publicado 2018
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
75por Song, Jian, Shi, Hongyu, Liao, Zhenhua, Wang, Song, Liu, Yuhong, Liu, Weiqiang, Peng, Zhongxiao“…Nanoindentation tests with a Berkovich indenter and nanoscratch experiments with a diamond stylus were performed on PEEK and CFRPEEK samples. …”
Publicado 2018
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
76por Condò, Roberta, Mampieri, Gianluca, Pasquantonio, Guido, Giancotti, Aldo, Pirelli, Paola, Cataldi, Maria Elena, La Rocca, Serena, Leggeri, Andrea, Notargiacomo, Andrea, Maiolo, Luca, De Filippis, Patrizia, Cerroni, Loredana“…Scanning electron microscopy, combined with focus ion bean micromachining and stylus profilometry analyses, were performed to evaluate the compositional factors that can influence specific pivotal properties facilitating the adhesion of bacteria to the surface, such as surface roughness and robustness of three orthodontic adhesive composite resins. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
77por Pöller, Franziska, Salazar Bloise, Félix, Jakobi, Martin, Dong, Jie, Koch, Alexander W.“…For comparison, the reference values of the sample roughness were also generated by measurements with a stylus profiler.…”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
78“…The cutting tools were prepared on a computer numerical control (CNC) lathe and roughness average (R(a)) and average maximum peak to valley height of the profile (R(z)) parameters were measured by contact stylus. The tip radius of the TC inserts used was determined to be the most significant factor that impacted R(a) and R(z). …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
79por Strobl, Klara, Selivanovitch, Ekaterina, Ibáñez-Freire, Pablo, Moreno-Madrid, Francisco, Schaap, Iwan A. T., Delgado-Buscalioni, Rafael, Douglas, Trevor, de Pablo, Pedro J.“…The authors explore individual virus cages to monitor their emission signal with total internal reflection fluorescence microscopy while simultaneously changing the microenvironment with the stylus of atomic force microscopy. The mechanical and electronic quenching can be decoupled by ≈10% each using insulator and conductive tips, respectively. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
80por Podulka, Przemysław“…Analysed surfaces were measured with a stylus or via non-contact (optical–white light interferometry) methods. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso