-
1por Teległów, Aneta, Marchewka, Jakub, Tota, Łukasz, Mucha, Dawid, Ptaszek, Bartłomiej, Makuch, Robert, Mucha, Dariusz“…The XTERRA Poland 2017 event comprised 1500-m swimming, 36-km cycling, and 10-km mountain running. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2por Goswami, Dipanjan, Gurule, Sanjay, Lahiry, Abhiroop, Anand, Amit, Khuroo, Arshad, Monif, Tausif“…MATERIALS & METHODS: Chromatographic separation was carried on XTerra(®) RP18 column (150 mm × 4.6 mm, 5 µm particle size) manufactured by Waters Corporation, MA, USA. …”
Publicado 2016
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
3“…A simple, specific and accurate reverse phase high performance liquid chromatographic method was developed for the determination of cyclosporine in capsule dosage form. XTerra C18 column was used as stationary phase with mobile phase acetonitrile in combination with 0.1% trifluoro acetic acid buffer and pH is adjusted to 1.4. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Texto -
4por Shabir, G. A.“…Chromatography was carried out on an XTerra RP18 (150×4.6 mm, 5 μm) column using 50 mM pyrrolidine (pH 11.5) – acetonitrile (50:50, v/v) as mobile phase at a flow rate of 1 ml/min. …”
Publicado 2011
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
5por Dong, Song-Tao, Li, Ying, Yang, Hao-Tian, Wu, Yin, Li, Ya-Jing, Ding, Cong-Yang, Meng, Lu, Dong, Zhan-Jun, Zhang, Yuan“…After protein precipitation with acetonitrile and sorafinib (internal standard, IS), they were chromatographed through a Waters XTerra MS C(18) column. The mobile phase was acetonitrile and water (including 0.1% ammonia). …”
Publicado 2018
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
6por Okaru, Alex O., Abuga, Kennedy O., Kamau, Franco N., Ndwigah, Stanley N., Lachenmeier, Dirk W.“…The stationary phase consisted of reverse-phase XTerra(®) (250 mm × 4.6 mm i.d., 5 µm particle size) maintained at a temperature of 43 °C with a UV detection at 215 nm. …”
Publicado 2017
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
7“…The chromatographic separation of analytes was successfully achieved on an XTerra(®) MS C(18) column using a gradient elution of methanol and water containing 0.1% formic acid at a flow rate of 0.5 mL/min. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
8por Ranganathan, Premanand, Gunasekaran, V., Singhvi, Indrajeet, Ansari, Mohammad Javed“…Lenalidomide is extracted from human plasma by Liquid- Liquid Extraction by Ethyl Acetate and analyzed using a reversed phase isocratic elution on a XTerra RP18, (4.6 × 50 mM, 5 µm) column. A 0.1% Formic acid: Methanol (10:90% v/v), is used as mobile phase and detection was performed by Triple quadrupole mass spectrometry LC-MS/MS using electrospray ionization in positive mode. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
9“…SSZ was optimally resolved from this product on an XTerra(®) RP18 column with a mobile phase composed of methanol and an ammonium acetate buffer (10 mM, pH 7.0) (48:52, v/v) delivered at a rate of 0.8 mL/min in an isocratic mode. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
10por Kalogria, Eleni, Varvaresou, Athanasia, Papageorgiou, Spyridon, Protopapa, Evaggelia, Tsaknis, Ioannis, Matikas, Alexios, Panderi, Irene“…Chromatographic separation was achieved on an XTerra MS C18 analytical column (150 × 3.0 mm i.d., particle size 5 μm) using a mobile phase of acetonitrile:water (15:85, v/v) containing 0.08 % trifluoroacetic acid at a flow rate of 0.30 mL min(−1). …”
Publicado 2014
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
11por Ogawa-Morita, Tomoko, Sano, Yoshiyuki, Okano, Tomoka, Fujii, Hirofumi, Tahara, Makoto, Yamaguchi, Masakazu, Minami, Hironobu“…Analyte (lenvatinib) and internal standard (IS, propranolol) in the plasma were extracted by using acetonitrile and chromatographically separated by using a XTerra MS C18 column with 0.2 mL/min flow and mobile phase starting with 0.1% formic acid in water, followed by increasing percentage of acetonitrile. …”
Publicado 2017
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
12por Guo, Na, Hu, Zhiwei, Fan, Xiaoxu, Zheng, Jian, Zhang, Dehui, Xu, Tao, Yu, Tao, Wang, Yang, Li, Haiying“…Samples were analyzed by LC-MS/MS on a reverse-phase xTerra MS C18 column which was equilibrated and eluted with an isocratic mixture of acetonitrile-water (1:9, v/v) at a flow rate of 0.3 mL/min. …”
Publicado 2012
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
13“…The chromatographic separation of ALD was carried on Xterra, RP-Column C18 (150 mm× 4.6 mm × 3.5 μm) at 30°C followed by four-step gradient program composed of methanol and water. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
14por Shu, Xiaoyun, Tang, Yuping, Jiang, Chenxue, Shang, Erxing, Fan, Xinshen, Ding, Anwei“…Seven compounds were analyzed simultaneously with a XTerra C(18) column (4.6 mm × 250 mm, 5 µm) using a linear gradient elution of a mobile phase containing acetonitrile (A) and a buffer solution (0.02 mol/L potassium dihydrogen phosphate and adjusted to pH 3 using phosphoric acid) (B); the flow rate was 1.0 mL/min. …”
Publicado 2012
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
15por Hossain, Mohammad F., Rashid, Mamoon, Sidhu, Rajjit, Mullins, Randy, Mayhew, Susan L.“…Chromatographic separation was achieved with a Shimadzu prominence HPLC system using isocratic elution mode on a Waters Xterra® MS C-18 column (4.6mm × 150mm, 5 μm) integrated with a XBridge® BEH C-18 Guard column (2.1mm × 5 mm, 5 μm). …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
16por Ekpenyong, Oscar, Cooper, Candace, Ma, Jing, Guy, Naihsuan C., Payan, Ashley N., Ban, Fuqiang, Cherkasov, Artem, Cox, Marc B., Liang, Dong, Xie, Huan“…An ultra-high-performance liquid chromatography (UHPLC) system equipped with a Waters XTerra MS C18 column was used for chromatographic separation by gradient elution with 0.1% (v/v) formic acid in water and methanol. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
17“…The analyses were performed on a Xterra C(18) column (4.6 × 100 mm, 5 µm) and UV detection at 280 nm. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
18por Thummala, Veera Raghava Raju, Tharlapu, Satya Sankarsana Jagan Mohan, Rekulapalli, Vijay Kumar, Ivaturi, Mrutyunjaya Rao, Nittala, Someswara Rao“…Efficient chromatographic separation was achieved on an XTerra RP18, 150 × 4.6 mm, 5 μm column using gradient elution at 230 nm detection wavelength. …”
Publicado 2014
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
19por Tota, Łukasz, Piotrowska, Anna, Pałka, Tomasz, Morawska, Małgorzata, Mikuľáková, Wioletta, Mucha, Dariusz, Żmuda-Pałka, Magdalena, Pilch, Wanda“…The study involved 15 triathletes whose objective for the season was to start in the XTERRA POLAND 2017 event (1,500-m swimming, 36-km cycling, and 10-km mountain running). …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
20por He, Sen, Chen, Hong-Tong, Zhao, Rui, Hu, Xin-Xin, Nie, Tong-Ying, Yang, Xin-Yi, Li, Cong-Ran, Lu, Xi, Wang, Xiu-Kun, Li, Xue, Lu, Yun, Li, Guo-Qing, Pang, Jing, You, Xue-Fu“…Sample pretreatment was achieved by liquid-liquid extraction with ethyl acetate, and separation was performed on an XTerra MS C(18) column (2.1×50 mm, 3.5 μm) with gradient elution (methanol and 0.1% formic acid) at a flow rate of 0.3 mL/min. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto