-
801“…Numerous treatments for hypoxic-ischemic brain injury caused by HIE have been developed over the last half century. Hypothermia, xenon gas treatment, the use of melatonin and erythropoietin, and hypoxic-ischemic preconditioning have proven effective in HIE patients. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
802por Johnson, Ulf, Engquist, Henrik, Lewén, Anders, Howells, Tim, Nilsson, Pelle, Ronne-Engström, Elisabeth, Rostami, Elham, Enblad, Per“…CBF was measured bedside with Xenon-enhanced CT (Xe-CT). The difference between actual CPP and CPPopt was calculated (CPP∆). …”
Publicado 2017
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
803“…The second method of clinical importance is a low-pressure (11)C-carbonylation technique that utilizes solvable xenon gas to effectively transfer and react [(11)C]carbon monoxide in a sealed reaction vessel. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
804“…In particular, we compare binding of xenon (Xe) to cucurbit[6]uril (CB6) with binding to cryptophane-A monoacid (CrA) in water as two different model systems. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
805por Rudek, Benedikt, Toyota, Koudai, Foucar, Lutz, Erk, Benjamin, Boll, Rebecca, Bomme, Cédric, Correa, Jonathan, Carron, Sebastian, Boutet, Sébastien, Williams, Garth J., Ferguson, Ken R., Alonso-Mori, Roberto, Koglin, Jason E., Gorkhover, Tais, Bucher, Maximilian, Lehmann, Carl Stefan, Krässig, Bertold, Southworth, Stephen H., Young, Linda, Bostedt, Christoph, Ueda, Kiyoshi, Marchenko, Tatiana, Simon, Marc, Jurek, Zoltan, Santra, Robin, Rudenko, Artem, Son, Sang-Kil, Rolles, Daniel“…Here we report results on multiple ionization of xenon atoms by ultra-intense (about 10(19) W/cm(2)) femtosecond X-ray pulses at photon energies from 5.5 to 8.3 keV and present a theoretical model capable of reproducing the experimental data in the entire energy range. …”
Publicado 2018
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
806por Gola, Alberto, Acerbi, Fabio, Capasso, Massimo, Marcante, Marco, Mazzi, Alberto, Paternoster, Giovanni, Piemonte, Claudio, Regazzoni, Veronica, Zorzi, Nicola“…PDE in excess of 20% at 175 nm was measured in liquid Xenon. In the paper, we discuss the specifications on the SiPM related to different types of applications, the SiPM design challenges and process optimizations, and the results from the experimental characterization of the different, NUV-sensitive technologies developed at FBK.…”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
807por Athron, Peter, Balázs, Csaba, Beniwal, Ankit, Bloor, Sanjay, Camargo-Molina, José Eliel, Cornell, Jonathan M., Farmer, Ben, Fowlie, Andrew, E. Gonzalo, Tomás, Kahlhoefer, Felix, Kvellestad, Anders, Martinez, Gregory D., Scott, Pat, Vincent, Aaron C., Wild, Sebastian, White, Martin, Williams, Anthony G.“…Our analysis includes up-to-date likelihood functions for the dark matter relic density, invisible Higgs decays, and direct and indirect searches for weakly-interacting dark matter including the latest XENON1T data. We also account for important uncertainties arising from the local density and velocity distribution of dark matter, nuclear matrix elements relevant to direct detection, and Standard Model masses and couplings. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
808por Chang, Yanhong, Lu, Wenjun, Guénolé, Julien, Stephenson, Leigh T., Szczpaniak, Agnieszka, Kontis, Paraskevas, Ackerman, Abigail K., Dear, Felicity F., Mouton, Isabelle, Zhong, Xiankang, Zhang, Siyuan, Dye, David, Liebscher, Christian H., Ponge, Dirk, Korte-Kerzel, Sandra, Raabe, Dierk, Gault, Baptiste“….%) were prepared using a xenon-plasma FIB microscope equipped with a cryogenic stage reaching −135 °C. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
809por Tobieson, Lovisa, Rossitti, Sandro, Zsigmond, Peter, Hillman, Jan, Marklund, Niklas“…METHODS: We evaluated 12 patients (median age 64; range 26-71 yr) for changes in CBF and energy metabolism following surgical ICH evacuation using Xenon-enhanced computed tomography (n = 10) or computed tomography perfusion (n = 2) for CBF and dual MD catheters, placed in the PHZ and the SNX at ICH surgery. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
810por Yamada, Hironao, Liu, Chang, Wu, Stephen, Koyama, Yukinori, Ju, Shenghong, Shiomi, Junichiro, Morikawa, Junko, Yoshida, Ryo“…In this study, to facilitate widespread use of transfer learning, we develop a pretrained model library called XenonPy.MDL. In this first release, the library comprises more than 140 000 pretrained models for various properties of small molecules, polymers, and inorganic crystalline materials. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
811por Athron, Peter, Balázs, Csaba, Bringmann, Torsten, Buckley, Andy, Chrząszcz, Marcin, Conrad, Jan, Cornell, Jonathan M., Dal, Lars A., Edsjö, Joakim, Farmer, Ben, Jackson, Paul, Kahlhoefer, Felix, Krislock, Abram, Kvellestad, Anders, McKay, James, Mahmoudi, Farvah, Martinez, Gregory D., Putze, Antje, Raklev, Are, Rogan, Christopher, Saavedra, Aldo, Savage, Christopher, Scott, Pat, Serra, Nicola, Weniger, Christoph, White, Martin“…We include the dark matter relic density measured by Planck, direct searches with LUX, PandaX, SuperCDMS and XENON100, limits on invisible Higgs decays from the Large Hadron Collider, searches for high-energy neutrinos from dark matter annihilation in the Sun with IceCube, and searches for gamma rays from annihilation in dwarf galaxies with the Fermi-LAT. …”
Publicado 2017
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
812“…This potentially resolves the long-standing mystery of Earth’s “missing xenon”, with regards to both Xe elemental depletion and isotopic fractionation in the atmosphere. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
813por Datesman, Aaron M.“…The 1979 accident at the Three Mile Island nuclear power station in Pennsylvania released about 22 million Curies of xenon-133 into the environment. Because physical dosimetry indicated exposures to the nearby population of less than about 2 mSv, discernible impacts to the health of the exposed population are not generally believed to have resulted. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
814“…Also, we find the speed of sound in the air at various temperatures, the speed of sound in each of Helium, Neon, Argon, Krypton, Xenon, Methane, Ethylene, Propylene, Propane, Hydrogen, Nitrogen, Fluorine, Chlorine, Oxygen, Nitrous oxide (laughing gas), Carbon dioxide, Nitric oxide, Carbon monoxide, Sulphur dioxide and dichlorodifluoromethane at room temperature. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
815“…The vacuum ultraviolet (VUV) scintillation light emitted by these Liquid argon (LAr) and liquid Xenon (LXe) detectors are shifted to higher wavelengths resulting in its efficient detection using the state-of-the-art photodetectors such as silicon photomultipliers (SiPM). …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
816por Nguyen Van, Minh, Mai, Oanh Le Thi, Pham Do, Chung, Lam Thi, Hang, Pham Manh, Cuong, Nguyen Manh, Hung, Pham Thi, Duyen, Do Danh, Bich“…FeCN7 sample exhibits the highest photocatalytic efficiency, decomposing almost completely RhB 10 ppm solution after 30 min of xenon lamp illumination with a reaction rate approximately ten times greater than that of pure g-C(3)N(4) nanosheet. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
817por Chaussade, Stanislas, Ali, Einas Abou, Hallit, Rachel, Belle, Arthur, Barret, Maximilien, Coriat, Romain“…Results The light source box contains a lamp, either Xenon or LED. The temperature of the light is high and is regulated by a forced-air cooling system to maintain a stable temperature in the middle of the box. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
818por Lee, Jae-Won, Cho, Joon Young, Kim, Mi Jeong, Kim, Jung Hoon, Park, Jong Hwan, Jeong, Seung Yol, Seo, Seon Hee, Lee, Geon-Woong, Jeong, Hee Jin, Han, Joong Tark“…Elastic composite films composed of the AgNPs-embedded SWCNTs, Ag flake, and polydimethylsiloxane are irradiated with radiation from a Xenon flash lamp within a time interval of one second for efficient sintering of conductive fillers. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
819por Squire, Marietta M., Munsamy, Megashnee, Lin, Gary, Telukdarie, Arnesh, Igusa, Takeru“…The study objective assessed the energy demand and economic cost of two hospital-based COVID-19 infection control interventions: negative pressure (NP) treatment rooms and xenon pulsed ultraviolet (XP-UV) equipment. After projecting COVID-19 hospitalizations, a Hospital Energy Model and Infection De-escalation Models quantified increases in energy demand and reductions in infections. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
820por Clancy, Neil T., Soares, António S., Bano, Sophia, Lovat, Laurence B., Chand, Manish, Stoyanov, Danail“…This paper describes a multispectral imaging (MSI) laparoscope that can derive quantitative measures of tissue oxygen saturation (SO(2)). The system uses a xenon surgical light source and fast filter wheel camera to capture eight narrow waveband images across the visible range in approximately 0.3 s. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto