Mostrando 12,821 - 12,840 Resultados de 13,922 Para Buscar 'TruTV~', tiempo de consulta: 1.11s Limitar resultados
  1. 12821
    “…Lattice structures built using material extrusion had lower accuracy and a lower relative density caused by the air gaps between layers, but had higher elastic moduli and larger energy absorption capacities, as a consequence of both the thicker struts and the relatively larger strength of the feedstock material. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  2. 12822
    “…The reduction of the pressure from atmospheric to 800 mbar did not have any effect on the cell size, strut thickness, and compression strength 10% of deformation, the Young modulus being even higher at 800 mbar. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  3. 12823
    “…A modified face-centered cubic (FCCm) lattice structure was designed to avoid the manufacturing problems that arise in the production of horizontal struts by laser powder bed fusion. The Gibson–Ashby curves of the FCCm lattice were obtained and it was found that relative density not only affects stiffness and strength of the structures, but also has important implications on the assumption of macroscopic yield criterion. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  4. 12824
    por Taams, Karel O., Taams, Stephanie J.
    Publicado 2022
    “…A bilateral trans alar forehead flap was used to reconstruct the nasal lining and columella in a patient with a severely contracted cocaine nose. An L strut cartilage graft was covered with the forehead flaps, which were divided and inset in the nasal vault separately 3 weeks apart. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  5. 12825
    por Heidari, Keemia S., Lalli, Trapper
    Publicado 2022
    “…Several augmentation strategies have been trialed in this setting, such as structural allografts, 3D printed implants, fibular strut grafts, to name a few. METHODS: We present a case describing TTC fusion for limb salvage utilizing a titanium mesh implant, combined with bone graft in the setting of massive bone deficit in an individual with Charcot arthropathy from Diabetes Mellitus and HIV after Pilon fracture, performed as revision procedure after failed Charcot reconstruction with a ringed external fixator and femoral head allograft with subsequent nonunion. …”
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  6. 12826
    por Richards, Gavin, Johnson, Thomas
    Publicado 2021
    “…Stent detail to the level of individual struts can be appreciated with intracoronary imaging, which facilitates appropriate stent selection and optimisation of the final stent result. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  7. 12827
    “…Probability density functions of projections of bubbles’ diameters and struts’ length are determined using images in three mutually perpendicular planes. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  8. 12828
    por Neha, Singh, Satya Vir
    Publicado 2022
    “…Its outstanding performance can be attributed to its unique morphology consisting of scaffolds having an extensively interconnected macroporous network with macropores having nanoporous struts as walls as evidenced by SEM results. Such morphology makes the active sites of inner pores accessible to the gaseous (air) as well solid reactant (soot particles), thereby benefitting soot oxidation reaction. …”
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  9. 12829
    “…The effects of the material Young’s modulus and Poisson’s ratio, strut diameter, cell size, and cell number on those equivalent mechanical properties were investigated and discussed, and the linear relationship with the material parameters and the non-linear relationship with the structural parameters were found. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  10. 12830
    “…While reoperation rates are higher in patients undergoing ORIF, arthroplasty longevity is a concern among young, active patients with high functional demands. Fibular strut allograft is a useful adjunct when reconstructing complex proximal humerus fractures. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  11. 12831
    “…Specifically, metalloporphyrin-based MOFs have been created where the porphyrin moieties are either incorporated as struts within the framework to form porphyrinic MOFs or encapsulated inside the cavities to construct porphyrin@MOFs which can combine the peerless properties of porphyrins and porous MOFs simultaneously. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  12. 12832
    “…ABSTRACT: Advances in stent technology and the design of endovascular devices with thinner struts, anti‐inflammatory and antithrombotic polymers, and better drug kinetics have enhanced the safety and efficacy of the second‐generation drug‐eluting stents and broadened their use in the therapy of high‐risk patients and complex anatomies. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  13. 12833
    “…These gels are based on a model system synthesized by the aqueous sol–gel processing of an ethylene-glycol-modified silane, resulting in a cellular, macroporous, strut-based network comprising anisotropic, periodically arranged mesopores formed by microporous amorphous silica. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  14. 12834
    “…Polyurethane elastomers were used to produce the graft and to coat the metallic struts of the stent to render it in vivo weldable. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  15. 12835
    “…The more rigid boot that constrained ankle angle using a posterior strut reduced tendon loading by 77% compared to gait in a normal walking shoe. …”
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  16. 12836
    “…Titanium mesh cages (TMC), allogeneic bone (ALB), and autogenous bone (AUB) are three main bone graft struts. We aimed to compare the therapeutic efficacy of three bone graft struts, for anterior and middle column reconstruction through a posterior approach in cases of mid‐thoracic spinal tuberculosis. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  17. 12837
    por Camarillo, Itzel
    Publicado 2020
    “…Las obras dialogan con la realidad del escritor, como en el caso del joven dramaturgo Jorge Maldonado, quien nació en la Ciudad de México (1988).1 En el año 2018, publicó su obra Last Man Standing, simulacro boxístico para actores, como parte de la Antología de TeatroSinParedes y la estrenó en conjunto con el colectivo del mismo nombre el pasado 29 de abril de 2019, en el foro La Gruta del Centro Cultural Helénico. Recibido: 01 de octubre de 2019Aceptado: 16 de diciembre de 2019…”
    Enlace del recurso
    Enlace del recurso
    Online Artículo
  18. 12838
    “…This study optimized and proposed a Warren truss slot-hole structure with a double-sided, square shallow slot and vertical and horizontal corrugated symmetry, achieved with inclined holes based on the stability and a good bearing capacity of an inclined strut truss structure. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  19. 12839
    “…Based on the experimental studies, it was found that tested structures exhibited different cell strut deformation mechanisms (bending-dominated and stretch-dominated) and overall deformation modes (uniform and “layer-by-layer”) depending on structural parameters. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  20. 12840
    “…The membrane has the following key characteristics: (a) It contains a panel of honeycomb structures, thereby efficiently handling motion stress through the entire membrane; (b) a strut is added into each honeycomb in a direction perpendicular to gravity, thereby suppressing the deformation and stress concentration upon lying and standing; and (c) thermo-responsive moldable elastomers are used to support structural holding by suppressing large deviations of movement that occur sporadically. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
Herramientas de búsqueda: RSS