Mostrando 12,941 - 12,960 Resultados de 13,922 Para Buscar 'TruTV~', tiempo de consulta: 1.17s Limitar resultados
  1. 12941
    “…Compared with the control animals, the methotrexate-treated animals showed lower rates of lipid-rich intima and per-strut low-signal intensity layers, smaller neointimal areas, and reduced neointimal thickness; larger fibrous cap thicknesses and smaller lumen areas were also seen in the animals receiving methotrexate. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  2. 12942
    “…It consisted mostly of a porous mesh and incorporated a dense strut. After 3-months of neoadjuvant chemotherapy, the patient underwent hemisacretomy with preservation of contralateral sacral nerves. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  3. 12943
    “…Of the 12 stent thrombosis cases, 4 occurred at a bare-metal stent (average time from stent implantation, 106 months); in all 12, significant neointimal hyperplasia was observed on IVUS, and 2 had plaque ruptures at an in-stent or proximal reference. Malapposed stent struts were observed in three very-late stent thromboses, and all of these underwent sirolimus-eluting stent implantation. …”
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  4. 12944
    “…Ankle, knee and hip joint mechanics were described and compared using angles, moments, powers and normalized functional indexes that described each joint as relatively more: spring, motor, damper or strut-like. To accelerate using a walking gait, the ankle joint was switched from predominantly spring-like to motor-like, while the hip joint was maintained as a motor, with an increase in hip motor-like function. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  5. 12945
    por Choi, Seung-Jun
    Publicado 2016
    “…Fixed-end or isometric contractions stabilize joints and allow muscles to act as active struts during locomotion. Active muscles dissipate energy when they are lengthened by an external force that exceeds their current force producing capacity. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  6. 12946
    “…In the vertebrae, spaceflight decreased the overall bone volume and altered the modulus in the periphery of the trabecular struts. Despite normalized osteoclastic activity and an increased osteoblast number, bone recovery was not observed 8 days after landing. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  7. 12947
    “…The typical full hysteretic loop for DSP could be divided into three distinct stages of behaviour: packing stage, constant friction stage and equivalent strut stage. The connection between the panel and the frame had a great effect on the transferring of different mechanical stages. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  8. 12948
    “…Scaffolds were characterised considering pore size, porosity, strut width, degradation behaviour and mechanical stability. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  9. 12949
    “…The fabricated ceramic structure consisted of layer-by-layered struts entangled with polycaprolactone microfibers and the bioceramic phase. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  10. 12950
    “…The specific biological effect of fibrinogen additions into cross-linked collagen are considered by using films as a model for the struts of bulk scaffolds. By considering various additions of fibrinogen to the collagen film with increasing degrees of cross-linking, this study demonstrates a significant biological advantage with fibrinogen addition across the cross-linking concentrations typically applied to collagen-based scaffolds.…”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  11. 12951
    “…In both processes, the MTBD conformational change was regulated by the AAA4 module and the AAA5/Strut module.…”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  12. 12952
    “…The experimental results showed that the secondary phase (i.e. 10% magnesium substituting calcium silicate; CSM10) could readily improve the sintering property of the bioceramic composites (DIO/CSM10-x, x = 0–30) with increasing the CSM10 content from 0% to 30%, and the presence of the CSM10 also improved the biomimetic apatite mineralization ability in the pore struts of the scaffolds. Furthermore, the flexible strength (12.5–30 MPa) and compressive strength (14–37 MPa) of the 3D printed porous bioceramics remarkably increased with increasing CSM10 content, and the compressive strength of DIO/CSM10-30 showed a limited decay (from 37 MPa to 29 MPa) in the Tris buffer solution for a long time stage (8 weeks). …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  13. 12953
    “…Finite element analysis (FEA) showed that scaffold fabricated from the novel nanocomposite material has improved scaffolding ability, specifically that the strut thickness could be decreased compared to the conventional PLLA scaffold. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  14. 12954
    “…The donor site of the fibular cortical strut showed good regeneration in all patients. The Harris hip score significantly improved from 65% to 95%. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  15. 12955
    “…We analyze the mechanical stiffness of hierarchically structured silica monoliths synthesized via a sol–gel process, which possess a macroporous scaffold built of interconnected struts with hexagonally ordered cylindrical mesopores. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  16. 12956
    “…The electrical read-out of the cantilever movement is realized by piezo-resistive struts at the sides of the cantilever resonator that enable real-time tracking using a phase-locked loop (PLL) circuit. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  17. 12957
    “…An increase of porosity produced an increase of both compressive and tensile stresses and struts exhibited complex stress fields. Voronoi-based modeling was in accordance with experimental results in the literature in the case of the quasi-static condition and linear elastic region (below 1% strain). …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  18. 12958
    “…Monolithic samples consisted of a disordered macroporous network of struts formed by a 2D lattice of hexagonally ordered cylindrical mesopores and disordered micropores within the mesopore walls. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  19. 12959
    “…The first stage was posterior decompression with occipitocervical fusion and instrumentation, while the second was anterior decompression and iliac strut graft. Both operations performed using the surgical ultrasonic dissector. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  20. 12960
    por Shaat, Mohamed, Wagih, Ahmed
    Publicado 2020
    “…The unit cell is 3D assembled of hinged-struts. Specially designed spherical hinges were utilized to give constant Poisson’s ratios. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
Herramientas de búsqueda: RSS