Distributed low voltage power supply system for front end electronics of the TRT detector in ATLAS experiment

We present a low voltage power supply system which has to deliver to the front end electronics of the ATLAS TRT detector [1] ca. 23 kW of electrical power over the distance of 55 -106 m (which adds another 24 kW). The system has to operate in magnetic field and under radiation environment of the LHC...

Descripción completa

Detalles Bibliográficos
Autores principales: Hajduk, Zbigniew, Banas, E, Farthouat, P, Kisielewski, B, Lichard, P, Olszowska, J, Ryzhov, V, Cardiel-Sas, L
Lenguaje:eng
Publicado: CERN 2007
Materias:
Acceso en línea:https://dx.doi.org/10.5170/CERN-2007-001.379
http://cds.cern.ch/record/1028143