Testing of the Pole Face Winding crimpings Measurements carried out on the 100 PS main units before start up of the PS machine in 2007
The crimpings of the Pole Face Windings (PFW), used to connect the rectangular copper conductor of the main windings with its supply cable, could have defects due to the manufacture process. They could lead to an extensive high electrical resistance. To locate these defects, the PFW are powered with...