Cargando…

Partial pressure gauges

The determination of partial pressures in vacuum systems is usually performed by mass spectrometers. The most common type is the QMS. Quadrupole mass spectrometers were developed decades ago and have been used by vacuum specialists as a diagnostic tool since then. In the first part of the paper the...

Descripción completa

Detalles Bibliográficos
Autores principales: Peter, G J, Müller, N
Lenguaje:eng
Publicado: CERN 2007
Materias:
Acceso en línea:https://dx.doi.org/10.5170/CERN-2007-003.195
http://cds.cern.ch/record/1047066
_version_ 1780912782646968320
author Peter, G J
Müller, N
author_facet Peter, G J
Müller, N
author_sort Peter, G J
collection CERN
description The determination of partial pressures in vacuum systems is usually performed by mass spectrometers. The most common type is the QMS. Quadrupole mass spectrometers were developed decades ago and have been used by vacuum specialists as a diagnostic tool since then. In the first part of the paper the principles of these mass spectrometers are briefly reviewed together with the key features of the instruments. This is necessary to operate these instruments. In the second part the boundary conditions which arise from the application as residual gas analyser in UHV/XHV plants are described. These lead to special versions of mass spectrometers. Results obtained with these instruments and typical artefacts in mass spectra obtained in the UHV are discussed.
id cern-1047066
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2007
publisher CERN
record_format invenio
spelling cern-10470662019-09-30T06:29:59Zdoi:10.5170/CERN-2007-003.195http://cds.cern.ch/record/1047066engPeter, G JMüller, NPartial pressure gaugesAccelerators and Storage RingsThe determination of partial pressures in vacuum systems is usually performed by mass spectrometers. The most common type is the QMS. Quadrupole mass spectrometers were developed decades ago and have been used by vacuum specialists as a diagnostic tool since then. In the first part of the paper the principles of these mass spectrometers are briefly reviewed together with the key features of the instruments. This is necessary to operate these instruments. In the second part the boundary conditions which arise from the application as residual gas analyser in UHV/XHV plants are described. These lead to special versions of mass spectrometers. Results obtained with these instruments and typical artefacts in mass spectra obtained in the UHV are discussed.CERNoai:cds.cern.ch:10470662007
spellingShingle Accelerators and Storage Rings
Peter, G J
Müller, N
Partial pressure gauges
title Partial pressure gauges
title_full Partial pressure gauges
title_fullStr Partial pressure gauges
title_full_unstemmed Partial pressure gauges
title_short Partial pressure gauges
title_sort partial pressure gauges
topic Accelerators and Storage Rings
url https://dx.doi.org/10.5170/CERN-2007-003.195
http://cds.cern.ch/record/1047066
work_keys_str_mv AT petergj partialpressuregauges
AT mullern partialpressuregauges