LHC Machine Protection

For nominal beam parameters at 7 TeV/c each of the two LHC proton beams has a stored energy of 362 MJ threatening to damage accelerator equipment in case of uncontrolled beam loss. The energy stored in the magnet system at 7 TeV/c will exceed 10 GJ. In order to avoid damage of accelerator equipment,...

Descripción completa

Detalles Bibliográficos
Autores principales: Schmidt, R, Assmann, Ralph Wolfgang, Carlier, E, Dehning, B, Denz, R, Goddard, B, Holzer, E B, Kain, V, Puccio, B, Todd, B, Uythoven, J, Wenninger, J, Zerlauth, M
Lenguaje:eng
Publicado: 2007
Materias:
Acceso en línea:https://dx.doi.org/10.1109/PAC.2007.4441111