Determination of fault operation dynamical constraints for the design of wind turbine DFIG drives
This paper presents an efficient design tool for the estimation of the transient electromagnetic peak torque and transient rotor over-voltages of wind turbines (WT) doubly-fed induction generators (DFIG) during severe fault conditions on the grid side. This versatile and robust tool is well adapted...