Cargando…
Production and Quality Assurance of Main Busbar Interconnection Splices during the LHC 2008-2009 Shutdown.
The main busbar interconnection splices of the Large Hadron Collider are assembled by inductive soldering of the Rutherford type cables and the copper profiles of the stabilizer. Following the September 2008 incident, the assembly process and the quality assurance have been improved, with new measur...
Autores principales: | Bertinelli, F, Bottura, L, Dalin, J-M, Fessia, P, Flora, R H, Heck, S, Pfeffer, H, Prin, H, Scheuerlein, C, Thonet, P, Tock, J-P, Williams, L |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TASC.2010.2085072 http://cds.cern.ch/record/1379836 |
Ejemplares similares
-
Nondestructive Testing and Quality Control of the LHC Main Interconnection Splices
por: Heck, S, et al.
Publicado: (2015) -
Electrical resistance and mechanical strength of LHC busbar cable splices as a function of intercable contact length
por: Heck, S, et al.
Publicado: (2011) -
Measurements of the Resistance of Main Circuit Busbar Segments at the LHC at Warm
por: Koratzinos, M, et al.
Publicado: (2010) -
Development of a New Insulation Approach for the LHC Main 13 kA Interconnection Splices
por: Lackner, F, et al.
Publicado: (2012) -
Busbar technology development for the HL-LHC inner triplet magnets
por: Tsolakis, E, et al.
Publicado: (2020)