Cargando…

Design of a Compact Dump Resistor System for LCD Magnet

In this technical note we suggest a possible solution for the choice of the detector magnet dump resistor. The push-pull scenario for Linear Collider Detectors imposes new solutions for magnet powering and protection lines, else than what developed for LHC detectors. The magnet dump resistor is the...

Descripción completa

Detalles Bibliográficos
Autores principales: Gaddi, A, Ramos, F
Lenguaje:eng
Publicado: 2010
Materias: