Cargando…
Three-gradient Emittance Measurements at REX-ISOLDE
The transverse emittance was measured using the three-gradient method (also known as the quadrupole scan method) and compared to the slit-grid method that is normally used at REX-ISOLDE. For a 2.85 MeV/u beam with A=q = 4 the rms normalised emittance was measured as 0:32 0:06 mm mrad with the three...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2013
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1517851 |