Cargando…

1% calibration errors in MQY magnets

Errors in the range of 1% have been observed for the MQY magnets in beam-based measurements. Furthermore, inconsistencies have been observed when comparing previous magnetic measurements to the LHC LSA database. After a revision, new calibration data have been extracted and were compared to the opti...

Descripción completa

Detalles Bibliográficos
Autores principales: Bach, T, Hagen, Per, Langner, A, Levinsen, Y, McAteer, M, Maclean, E H, Persson, T, Skowronski, P, Tomás, R, Todesco, E, White, S
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/1545888