Equalisation of the PMT response to charge particles for the LUCID detector of the ATLAS experiment
With a view to the Run II of LHC, 44 Hamamatsu R760 PMTs have been calibrated with a 207Bi source. The working point of each PMT has been xed in order to equalise the PMT gain at a value smaller than $10^{5}$. Studies on the reproducibility and the stability in time of such calibration permitted to...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1753814 |
_version_ | 1780943261203955712 |
---|---|
author | Vittori, Camilla |
author_facet | Vittori, Camilla |
author_sort | Vittori, Camilla |
collection | CERN |
description | With a view to the Run II of LHC, 44 Hamamatsu R760 PMTs have been calibrated with a 207Bi source. The working point of each PMT has been xed in order to equalise the PMT gain at a value smaller than $10^{5}$. Studies on the reproducibility and the stability in time of such calibration permitted to reach a 5% accuracy on PMT gain. In addition, an evaluation of the relative gain of 10 modied PMTs has been performed. |
id | cern-1753814 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | cern-17538142019-09-30T06:29:59Zhttp://cds.cern.ch/record/1753814engVittori, CamillaEqualisation of the PMT response to charge particles for the LUCID detector of the ATLAS experimentDetectors and Experimental TechniquesParticle Physics - ExperimentWith a view to the Run II of LHC, 44 Hamamatsu R760 PMTs have been calibrated with a 207Bi source. The working point of each PMT has been xed in order to equalise the PMT gain at a value smaller than $10^{5}$. Studies on the reproducibility and the stability in time of such calibration permitted to reach a 5% accuracy on PMT gain. In addition, an evaluation of the relative gain of 10 modied PMTs has been performed.CERN-STUDENTS-Note-2014-174oai:cds.cern.ch:17538142014-09-05 |
spellingShingle | Detectors and Experimental Techniques Particle Physics - Experiment Vittori, Camilla Equalisation of the PMT response to charge particles for the LUCID detector of the ATLAS experiment |
title | Equalisation of the PMT response to charge particles for the LUCID detector of the ATLAS experiment |
title_full | Equalisation of the PMT response to charge particles for the LUCID detector of the ATLAS experiment |
title_fullStr | Equalisation of the PMT response to charge particles for the LUCID detector of the ATLAS experiment |
title_full_unstemmed | Equalisation of the PMT response to charge particles for the LUCID detector of the ATLAS experiment |
title_short | Equalisation of the PMT response to charge particles for the LUCID detector of the ATLAS experiment |
title_sort | equalisation of the pmt response to charge particles for the lucid detector of the atlas experiment |
topic | Detectors and Experimental Techniques Particle Physics - Experiment |
url | http://cds.cern.ch/record/1753814 |
work_keys_str_mv | AT vittoricamilla equalisationofthepmtresponsetochargeparticlesfortheluciddetectoroftheatlasexperiment |