Cargando…
Design of a 4 Rod Crab Cavity Cryomodule System for HL-LHC
The LHC requires compact SRF crab cavities for the HL-LHC and 3 potential solutions are under consideration. One option is to develop a 4 rod cavity utilising for quarter wave rods to maintain a dipole field. The cavity design has been developed including power and LOM/HOM couplers have been develop...
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2013
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2063910 |