Cargando…

A High Granular Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept description and first beam test results

The expected increase of the particle flux at the high luminosity phase of the LHC (HL-LHC) with instantaneous luminosities up to L ≃ 7.5 × 1034 cm−2 s-1 will have a severe impact on the ATLAS detector performance. The pile-up is expected to increase on average to 200 interactions per bunch crossing...

Descripción completa

Detalles Bibliográficos
Autor principal: Lacour, Didier
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:http://cds.cern.ch/record/2286829
_version_ 1780955987314737152
author Lacour, Didier
author_facet Lacour, Didier
author_sort Lacour, Didier
collection CERN
description The expected increase of the particle flux at the high luminosity phase of the LHC (HL-LHC) with instantaneous luminosities up to L ≃ 7.5 × 1034 cm−2 s-1 will have a severe impact on the ATLAS detector performance. The pile-up is expected to increase on average to 200 interactions per bunch crossing. The reconstruction and trigger performance for electrons, photons as well as jets and transverse missing energy will be severely degraded in the end-cap and forward region, where the liquid Argon based electromagnetic calorimeter has coarser granularity compared to the central region. A High Granularity Timing Detector (HGTD) is proposed in front of the liquid Argon end-cap calorimeters for pile-up mitigation at Level-0 (L0) trigger level and in the offline reconstruction. This device should cover the pseudo-rapidity range of 2.4 to about 4.2. Four layers of Silicon sensors are foreseen to provide a precision timing information for minimum ionizing particle with a time resolution better than 50 pico-seconds per readout cell in order to assign the particle to the correct vertex. Each readout cell has a transverse size of 1.3 mm × 1.3 mm leading to a highly granular detector with more than 6 millions of readout electronics channels. Low Gain Avalanche Detectors (LGAD) technology has been chosen as it provides an internal gain good enough to reach large signal over noise ratio needed for excellent time resolution. The requirements and overall specifications of the High Granular Timing Detector at the HL-LHC will be presented as well as the conceptual design of its mechanics and electronics. Beam test results and measurements of irradiated LGAD silicon sensors, such as gain and timing resolution, will be shown.
id cern-2286829
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling cern-22868292019-09-30T06:29:59Zhttp://cds.cern.ch/record/2286829engLacour, DidierA High Granular Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept description and first beam test resultsParticle Physics - ExperimentThe expected increase of the particle flux at the high luminosity phase of the LHC (HL-LHC) with instantaneous luminosities up to L ≃ 7.5 × 1034 cm−2 s-1 will have a severe impact on the ATLAS detector performance. The pile-up is expected to increase on average to 200 interactions per bunch crossing. The reconstruction and trigger performance for electrons, photons as well as jets and transverse missing energy will be severely degraded in the end-cap and forward region, where the liquid Argon based electromagnetic calorimeter has coarser granularity compared to the central region. A High Granularity Timing Detector (HGTD) is proposed in front of the liquid Argon end-cap calorimeters for pile-up mitigation at Level-0 (L0) trigger level and in the offline reconstruction. This device should cover the pseudo-rapidity range of 2.4 to about 4.2. Four layers of Silicon sensors are foreseen to provide a precision timing information for minimum ionizing particle with a time resolution better than 50 pico-seconds per readout cell in order to assign the particle to the correct vertex. Each readout cell has a transverse size of 1.3 mm × 1.3 mm leading to a highly granular detector with more than 6 millions of readout electronics channels. Low Gain Avalanche Detectors (LGAD) technology has been chosen as it provides an internal gain good enough to reach large signal over noise ratio needed for excellent time resolution. The requirements and overall specifications of the High Granular Timing Detector at the HL-LHC will be presented as well as the conceptual design of its mechanics and electronics. Beam test results and measurements of irradiated LGAD silicon sensors, such as gain and timing resolution, will be shown.ATL-LARG-SLIDE-2017-858oai:cds.cern.ch:22868292017-10-02
spellingShingle Particle Physics - Experiment
Lacour, Didier
A High Granular Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept description and first beam test results
title A High Granular Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept description and first beam test results
title_full A High Granular Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept description and first beam test results
title_fullStr A High Granular Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept description and first beam test results
title_full_unstemmed A High Granular Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept description and first beam test results
title_short A High Granular Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept description and first beam test results
title_sort high granular timing detector for the phase-ii upgrade of the atlas calorimeter system: detector concept description and first beam test results
topic Particle Physics - Experiment
url http://cds.cern.ch/record/2286829
work_keys_str_mv AT lacourdidier ahighgranulartimingdetectorforthephaseiiupgradeoftheatlascalorimetersystemdetectorconceptdescriptionandfirstbeamtestresults
AT lacourdidier highgranulartimingdetectorforthephaseiiupgradeoftheatlascalorimetersystemdetectorconceptdescriptionandfirstbeamtestresults