Cargando…

Performance of a spaghetti calorimeter prototype with tungsten absorber and garnet crystal fibres

A spaghetti calorimeter (SPACAL) prototype with scintillating crystal fibres was assembled and tested with electron beams of energy from 1 to 5 GeV. The prototype comprised radiation-hard Cerium-doped Gd<math display="inline" id="d1e435" altimg="si1.svg"><msub&...

Descripción completa

Detalles Bibliográficos
Autores principales: An, Liupan, Auffray, Etiennette, Betti, Federico, Dall'Omo, Frederik, Gascon, David, Golutvin, Andrey, Guz, Yury, Kholodenko, Sergey, Martinazzoli, Loris, De Cos, José Mazorra, Picatoste, Eduardo, Pizzichemi, Marco, Roloff, Philipp, Salomoni, Matteo, Sanchez, David, Schopper, Andreas, Semennikov, Aleksandr, Shatalov, Pavel, Shmanin, Evgenii, Strekalina, Daria, Zhang, Yanxi
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2022.167629