Cargando…

Test Results of the MQYYM: A 90 Mm NbTi Quadrupole Magnet Option for HL-LHC

For the HL-LHC project, a 90 mm NbTi cos(2θ) double aperture quadrupole magnet with an operating gradient of 120 T/m at 1.9 K has been designed as an option to replace the 70 mm aperture LHC quadrupole MQY. CEA in collaboration with CERN designed and manufactured a single aperture short model magnet...

Descripción completa

Detalles Bibliográficos
Autores principales: Simon, D, Perraud, S, Felice, H, Godon, R, Machado, R Correia, Gheller, J M, Bouziat, D, Stepanov, V, Madur, A, Segreti, M, Molinié, F, Hervieu, B, Antoni, P De, Guihard, Q, Relland, J, Perez, J C, Foussat, A, Petrone, C, Fiscarelli, L, Bonora, M, Todesco, E
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TASC.2022.3163076
http://cds.cern.ch/record/2859849