The effects of radiation on gallium arsenide radiation detectors

Semi-insulating, undoped, Liquid Encapsulated Czochralski (SI-U LEC) GaAs detectors have been irradiated with 1MeV neutrons, 24GeV/c protons, and 300MeV/c pions. The maximum fluences used were 6, 3, and 1.8~10$^{14}$ particles/cm$^{2}$ respectively. For all three types of irradiation the charge coll...

Descripción completa

Detalles Bibliográficos
Autores principales: Bates, R.L., Da'Via, C., D'Auria, S., O'Shea, V., Raine, C., Smith, K.M.
Lenguaje:eng
Publicado: 1997
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(97)00628-1