Cargando…
Space charge in ionization detectors and the NA48 electromagnetic calorimeter
The subject of space charge due to positive ions slowly moving in parallel plate ionization chambers is considered. A model for the degradation of the detector response is developed, with particular emphasis on electromagnetic calorimeters. The topics discussed include: (a) the stationary and (b) th...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1998
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(98)01193-0 http://cds.cern.ch/record/369960 |
_version_ | 1780893072184311808 |
---|---|
author | Palestini, S Barr, Giles David Ceccucci, Augusto Cogan, J Cundy, Donald C Fischer, G Funk, W Gianoli, A Gonidec, A Govi, G Kubischta, Werner Luitz, S Norton, Alan Robert Schinzel, D Velasco, M Vossnack, O Wahl, H Kekelidze, V D Tatishvili, G T Tkachev, A L Formica, A Frabetti, P L Martini, M Chollet, J C Crépé, S Fayard, Louis Iconomidou-Fayard, L Ocariz, J Unal, G Calafiura, P Cerri, C Cirilli, M Costantini, F Fantechi, R Giudici, Sergio Gorini, B Mannelli, I Sozzi, M Biino, C Mikulec, I |
author_facet | Palestini, S Barr, Giles David Ceccucci, Augusto Cogan, J Cundy, Donald C Fischer, G Funk, W Gianoli, A Gonidec, A Govi, G Kubischta, Werner Luitz, S Norton, Alan Robert Schinzel, D Velasco, M Vossnack, O Wahl, H Kekelidze, V D Tatishvili, G T Tkachev, A L Formica, A Frabetti, P L Martini, M Chollet, J C Crépé, S Fayard, Louis Iconomidou-Fayard, L Ocariz, J Unal, G Calafiura, P Cerri, C Cirilli, M Costantini, F Fantechi, R Giudici, Sergio Gorini, B Mannelli, I Sozzi, M Biino, C Mikulec, I |
author_sort | Palestini, S |
collection | CERN |
description | The subject of space charge due to positive ions slowly moving in parallel plate ionization chambers is considered. A model for the degradation of the detector response is developed, with particular emphasis on electromagnetic calorimeters. The topics discussed include: (a) the stationary and (b) the time dependent cases; (c) the limit of very large space charge; (d) the electric field dependence of the electron drift velocity; (e) the effect of longitudinal development of showers; (f) the behavior of the average reductions of response and (g) the non-uniformity of response for different positions of the shower axis inside the cell defined by the electrodes. The NA48 calorimeter is used as application and for comparison of results. |
id | cern-369960 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1998 |
record_format | invenio |
spelling | cern-3699602019-09-30T06:29:59Zdoi:10.1016/S0168-9002(98)01193-0http://cds.cern.ch/record/369960engPalestini, SBarr, Giles DavidCeccucci, AugustoCogan, JCundy, Donald CFischer, GFunk, WGianoli, AGonidec, AGovi, GKubischta, WernerLuitz, SNorton, Alan RobertSchinzel, DVelasco, MVossnack, OWahl, HKekelidze, V DTatishvili, G TTkachev, A LFormica, AFrabetti, P LMartini, MChollet, J CCrépé, SFayard, LouisIconomidou-Fayard, LOcariz, JUnal, GCalafiura, PCerri, CCirilli, MCostantini, FFantechi, RGiudici, SergioGorini, BMannelli, ISozzi, MBiino, CMikulec, ISpace charge in ionization detectors and the NA48 electromagnetic calorimeterDetectors and Experimental TechniquesThe subject of space charge due to positive ions slowly moving in parallel plate ionization chambers is considered. A model for the degradation of the detector response is developed, with particular emphasis on electromagnetic calorimeters. The topics discussed include: (a) the stationary and (b) the time dependent cases; (c) the limit of very large space charge; (d) the electric field dependence of the electron drift velocity; (e) the effect of longitudinal development of showers; (f) the behavior of the average reductions of response and (g) the non-uniformity of response for different positions of the shower axis inside the cell defined by the electrodes. The NA48 calorimeter is used as application and for comparison of results.CERN-EP-98-165oai:cds.cern.ch:3699601998-06-03 |
spellingShingle | Detectors and Experimental Techniques Palestini, S Barr, Giles David Ceccucci, Augusto Cogan, J Cundy, Donald C Fischer, G Funk, W Gianoli, A Gonidec, A Govi, G Kubischta, Werner Luitz, S Norton, Alan Robert Schinzel, D Velasco, M Vossnack, O Wahl, H Kekelidze, V D Tatishvili, G T Tkachev, A L Formica, A Frabetti, P L Martini, M Chollet, J C Crépé, S Fayard, Louis Iconomidou-Fayard, L Ocariz, J Unal, G Calafiura, P Cerri, C Cirilli, M Costantini, F Fantechi, R Giudici, Sergio Gorini, B Mannelli, I Sozzi, M Biino, C Mikulec, I Space charge in ionization detectors and the NA48 electromagnetic calorimeter |
title | Space charge in ionization detectors and the NA48 electromagnetic calorimeter |
title_full | Space charge in ionization detectors and the NA48 electromagnetic calorimeter |
title_fullStr | Space charge in ionization detectors and the NA48 electromagnetic calorimeter |
title_full_unstemmed | Space charge in ionization detectors and the NA48 electromagnetic calorimeter |
title_short | Space charge in ionization detectors and the NA48 electromagnetic calorimeter |
title_sort | space charge in ionization detectors and the na48 electromagnetic calorimeter |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(98)01193-0 http://cds.cern.ch/record/369960 |
work_keys_str_mv | AT palestinis spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT barrgilesdavid spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT ceccucciaugusto spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT coganj spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT cundydonaldc spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT fischerg spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT funkw spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT gianolia spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT gonideca spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT govig spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT kubischtawerner spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT luitzs spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT nortonalanrobert spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT schinzeld spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT velascom spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT vossnacko spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT wahlh spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT kekelidzevd spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT tatishviligt spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT tkacheval spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT formicaa spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT frabettipl spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT martinim spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT cholletjc spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT crepes spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT fayardlouis spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT iconomidoufayardl spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT ocarizj spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT unalg spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT calafiurap spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT cerric spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT cirillim spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT costantinif spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT fantechir spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT giudicisergio spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT gorinib spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT mannellii spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT sozzim spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT biinoc spacechargeinionizationdetectorsandthena48electromagneticcalorimeter AT mikuleci spacechargeinionizationdetectorsandthena48electromagneticcalorimeter |