Cargando…
Test beam results on resistive plate chamber prototype at gamma irradiation facility in CERN
We report recent results on performances of 2 mm double-gap RPC operated with the CERN SPS X5 120 GeV muon beams under high rate /sup 137/Cs irradiation. We obtained the efficiency and time resolution and other related physical parameters. This was done for a three component gas mixture: (C/sub 2/H/...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1999
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(99)00268-5 http://cds.cern.ch/record/410827 |