Cargando…
The Influence of Air Exposures and Thermal Treatments on the Secondary Electron Yield of Copper
The variation of the secondary electron yield (SEY) of sputter-cleaned OFHC-copper has been studied as a function of air exposure duration at room temperature. After short air exposures of some seconds the maximum SEY (deltaMAX) of clean copper is reduced from 1.3 to less than 1.2, due to the oxidat...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1116/1.582286 http://cds.cern.ch/record/434211 |