Radiation tests on commercial instrumentation amplifiers, analog switches & DAC's
A study of several commercial instrumentation amplifiers (INA110, INA111, INA114, INA116, INA118 & INA121) under neutron and vestigial gamma radiation was done. Some parameters (Gain, input offset voltage, input bias currents) were measured on-line and bandwidth, and slew rate were determined be...