Radiation tests on commercial instrumentation amplifiers, analog switches & DAC's

A study of several commercial instrumentation amplifiers (INA110, INA111, INA114, INA116, INA118 & INA121) under neutron and vestigial gamma radiation was done. Some parameters (Gain, input offset voltage, input bias currents) were measured on-line and bandwidth, and slew rate were determined be...

Descripción completa

Detalles Bibliográficos
Autores principales: Agapito, J A, Barradas, N P, Cardeira, F M, Casas, C, Fernandes, A, Franco, F J, Gomes, P, Gonçalves, I C, Cachero, A H, Lozano-Bahilo, J, Marques, J G, Paz, A, Prata, M J, Ramalho, A J G, Rodríguez-Ruiz, M A, Santos, J P, Vieira, A