Readout of non irradiated and irradiated strip detectors with fast analogue electronic
Silicon strip detectors with 50 micron readout pitch were connected to fast analogue electronic (SCT 32A). Fast neutrons were used to irradiate detectors to two different fluences. Signal, noise and charge collection efficiency values were compared to the values before irradiation.
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1998
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/683762 |
_version_ | 1780901344189612032 |
---|---|
author | Cindro, V Kramberger, G Mikuz, M Zontar, D Kaplon, J Riedler, P Roe, S Weilhammer, Peter Dabrowski, W |
author_facet | Cindro, V Kramberger, G Mikuz, M Zontar, D Kaplon, J Riedler, P Roe, S Weilhammer, Peter Dabrowski, W |
author_sort | Cindro, V |
collection | CERN |
description | Silicon strip detectors with 50 micron readout pitch were connected to fast analogue electronic (SCT 32A). Fast neutrons were used to irradiate detectors to two different fluences. Signal, noise and charge collection efficiency values were compared to the values before irradiation. |
id | cern-683762 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1998 |
record_format | invenio |
spelling | cern-6837622019-09-30T06:29:59Zhttp://cds.cern.ch/record/683762engCindro, VKramberger, GMikuz, MZontar, DKaplon, JRiedler, PRoe, SWeilhammer, PeterDabrowski, WReadout of non irradiated and irradiated strip detectors with fast analogue electronicDetectors and Experimental TechniquesSilicon strip detectors with 50 micron readout pitch were connected to fast analogue electronic (SCT 32A). Fast neutrons were used to irradiate detectors to two different fluences. Signal, noise and charge collection efficiency values were compared to the values before irradiation.ATL-INDET-98-220oai:cds.cern.ch:6837621998-09-01 |
spellingShingle | Detectors and Experimental Techniques Cindro, V Kramberger, G Mikuz, M Zontar, D Kaplon, J Riedler, P Roe, S Weilhammer, Peter Dabrowski, W Readout of non irradiated and irradiated strip detectors with fast analogue electronic |
title | Readout of non irradiated and irradiated strip detectors with fast analogue electronic |
title_full | Readout of non irradiated and irradiated strip detectors with fast analogue electronic |
title_fullStr | Readout of non irradiated and irradiated strip detectors with fast analogue electronic |
title_full_unstemmed | Readout of non irradiated and irradiated strip detectors with fast analogue electronic |
title_short | Readout of non irradiated and irradiated strip detectors with fast analogue electronic |
title_sort | readout of non irradiated and irradiated strip detectors with fast analogue electronic |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/683762 |
work_keys_str_mv | AT cindrov readoutofnonirradiatedandirradiatedstripdetectorswithfastanalogueelectronic AT krambergerg readoutofnonirradiatedandirradiatedstripdetectorswithfastanalogueelectronic AT mikuzm readoutofnonirradiatedandirradiatedstripdetectorswithfastanalogueelectronic AT zontard readoutofnonirradiatedandirradiatedstripdetectorswithfastanalogueelectronic AT kaplonj readoutofnonirradiatedandirradiatedstripdetectorswithfastanalogueelectronic AT riedlerp readoutofnonirradiatedandirradiatedstripdetectorswithfastanalogueelectronic AT roes readoutofnonirradiatedandirradiatedstripdetectorswithfastanalogueelectronic AT weilhammerpeter readoutofnonirradiatedandirradiatedstripdetectorswithfastanalogueelectronic AT dabrowskiw readoutofnonirradiatedandirradiatedstripdetectorswithfastanalogueelectronic |