The liquid cooling system of the LHCb Inner Tracker: Design constraints and considerations

This note gives an overview of the design of the liquid cooling system for the silicon microstrip based Inner Tracker detector at LHCb. We compare the thermal performance of different liquid coolant options for the Inner Tracker bby calculating the best exchange parameters in a simplified cooling ge...