Performance and limitations of high granularity single photon processing X-ray imaging detectors

Progress in CMOS technology and in fine pitch bump bonding has made possible the development of single photon counting detectors for X-ray imaging with pixel pitches on the order of 50 µm giving a spatial resolution which is comparable to conventional CCD and flat panel detectors. This thesis studie...

Descripción completa

Detalles Bibliográficos
Autor principal: Tlustos, L
Lenguaje:eng
Publicado: Vienna, Tech. U. 2005
Materias:
Acceso en línea:http://cds.cern.ch/record/846447
_version_ 1780906861876215808
author Tlustos, L
author_facet Tlustos, L
author_sort Tlustos, L
collection CERN
description Progress in CMOS technology and in fine pitch bump bonding has made possible the development of single photon counting detectors for X-ray imaging with pixel pitches on the order of 50 µm giving a spatial resolution which is comparable to conventional CCD and flat panel detectors. This thesis studies the interaction of X-ray photons in the energy range of 5 keV to 70 keV with various sensor materials as well as the response of the Medipix2 readout system to both monochromatic and wide spectrum X-ray sources. Single photon processing offers the potential for spectroscopic imaging. However, this thesis demonstrates using simulations and measurements that the charge deposition and collection within the semiconductor sensor impose fundamental limits on the achievable energy resolution. In particular the discussion of charge during collection in the sensor and the generation of fluorescence photons in heavier sensor materials contribute to the appearance of a low energy tail on the detected spectrum of an incoming beam. On the other hand, with the application of appropriate flat-field correction maps, the systemem operates to the Poisson limit. As the electronic noise in a pixel channel is around 100e rms and typical energy thresholds are over 1000e excellent quality images of low contrast objects have been produced using both intense and weak X-ray sources. The Modulation Transfer Function has been measured to be 9.1 lp/mm corresponding to the pixel aperture function. The Detective Quantum Efficiency is only limited by the sensor material used and does not change as a function of dose, highlighting the enormous potential for low dose imaging with such a system. The Medipix2 system has an upper threshold in each pixel too which allows an energy window of down to 1.4 keV FWHM to be selected and scanned in the range of 4 keV to 100 keV. First images using the energy threshold window demonstrate the potential of the technique to extract a spectral image when only a broad band source of X-rays is available.
id cern-846447
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2005
publisher Vienna, Tech. U.
record_format invenio
spelling cern-8464472019-09-30T06:29:59Zhttp://cds.cern.ch/record/846447engTlustos, LPerformance and limitations of high granularity single photon processing X-ray imaging detectorsDetectors and Experimental TechniquesProgress in CMOS technology and in fine pitch bump bonding has made possible the development of single photon counting detectors for X-ray imaging with pixel pitches on the order of 50 µm giving a spatial resolution which is comparable to conventional CCD and flat panel detectors. This thesis studies the interaction of X-ray photons in the energy range of 5 keV to 70 keV with various sensor materials as well as the response of the Medipix2 readout system to both monochromatic and wide spectrum X-ray sources. Single photon processing offers the potential for spectroscopic imaging. However, this thesis demonstrates using simulations and measurements that the charge deposition and collection within the semiconductor sensor impose fundamental limits on the achievable energy resolution. In particular the discussion of charge during collection in the sensor and the generation of fluorescence photons in heavier sensor materials contribute to the appearance of a low energy tail on the detected spectrum of an incoming beam. On the other hand, with the application of appropriate flat-field correction maps, the systemem operates to the Poisson limit. As the electronic noise in a pixel channel is around 100e rms and typical energy thresholds are over 1000e excellent quality images of low contrast objects have been produced using both intense and weak X-ray sources. The Modulation Transfer Function has been measured to be 9.1 lp/mm corresponding to the pixel aperture function. The Detective Quantum Efficiency is only limited by the sensor material used and does not change as a function of dose, highlighting the enormous potential for low dose imaging with such a system. The Medipix2 system has an upper threshold in each pixel too which allows an energy window of down to 1.4 keV FWHM to be selected and scanned in the range of 4 keV to 100 keV. First images using the energy threshold window demonstrate the potential of the technique to extract a spectral image when only a broad band source of X-rays is available.Vienna, Tech. U.CERN-THESIS-2005-032oai:cds.cern.ch:8464472005
spellingShingle Detectors and Experimental Techniques
Tlustos, L
Performance and limitations of high granularity single photon processing X-ray imaging detectors
title Performance and limitations of high granularity single photon processing X-ray imaging detectors
title_full Performance and limitations of high granularity single photon processing X-ray imaging detectors
title_fullStr Performance and limitations of high granularity single photon processing X-ray imaging detectors
title_full_unstemmed Performance and limitations of high granularity single photon processing X-ray imaging detectors
title_short Performance and limitations of high granularity single photon processing X-ray imaging detectors
title_sort performance and limitations of high granularity single photon processing x-ray imaging detectors
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/846447
work_keys_str_mv AT tlustosl performanceandlimitationsofhighgranularitysinglephotonprocessingxrayimagingdetectors