Cargando…

Measurement of beam stability and coupling impedance by RF excitation

The transverse stability limit and coupling impedance of proton beams in the CERN intersecting storage rings have been measured by external excitation of the beam. The impedance values at low frequencies thus obtained are in good agreement with the sum of the skin-effect and the wall-inductance whic...

Descripción completa

Detalles Bibliográficos
Autores principales: Hofmann, A, Zotter, Bruno W
Lenguaje:eng
Publicado: 1977
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TNS.1977.4328987
http://cds.cern.ch/record/878538