Cargando…
Performance of a magnetized total absorption calorimeter between 15 GeV and 140 GeV
The authors have calibrated a magnetized iron-scintillator sandwich calorimeter in a hadron beam, finding an energy resolution equal to 16% fwhm at 140 GeV with 4 cm sampling. The hadron energy resolution (fwhm/mean) improves as E/sup -1/2/ between 15 and 140 GeV. No effect due to the magnetic field...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1977
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/0029-554X(78)90472-X http://cds.cern.ch/record/879171 |