Cargando…

Beam feasibility study of a collimator with in-jaw beam position monitors

At present, the beam-based alignment of the LHC collimators is performed by touching the beam halo with both jaws of each collimator. This method requires dedicated fills at low intensities that are done infrequently and makes this procedure time consuming. This limits the operational flexibility, i...

Descripción completa

Detalles Bibliográficos
Autores principales: Wollmann, Daniel, Nosych, Andriy A, Valentino, Gianluca, Aberle, Oliver, Aßmann, Ralph W, Bertarelli, Alessandro, Boccard, Christian, Bruce, Roderik, Burkart, Florian, Calvo, Eva, Cauchi, Marija, Dallocchio, Alessandro, Deboy, Daniel, Gasior, Marek, Jones, Rhodri, Kain, Verena, Lari, Luisella, Redaelli, Stefano, Rossi, Adriana
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2014.09.024
http://cds.cern.ch/record/2014681