Rotating Machinery for LHC Cryogenics: First Analysis of Reliability and Origins of Downtime
The Large Hadron Collider (LHC) is cooled by eight independent helium cryogenic plants. Each cryogenic plant combines an 18 kW at 4.5 K refrigerator and a 2.4 kW at 1.8 K refrigeration unit totaling 64 oil lubricated screw compressors, 74 expansion turbines and 28 cold hydrodynamic compressors. Sinc...