Secondary neutrons inside a proton therapy facility: MCNPX simulations compared to measurements performed with a Bonner Sphere Spectrometer and neutron H*(10) monitors

Neutron spectrometry measurements with an extended-range Bonner Sphere Spectrometer (BSS), as well as neutron H*(10) measurements using an extended-range rem meter WENDI-2, a conventional rem meter LB 6411 and a tissue-equivalent proportional counter, were performed inside and around the Fixed-Beam...

Descripción completa

Detalles Bibliográficos
Autores principales: De Smet, Valérie, De Saint-Hubert, Marijke, Dinar, Nesrine, Manessi, Giacomo Paolo, Aza, Eleni, Cassell, Christopher, Saldarriaga Vargas, Clarita, Van Hoey, Olivier, Mathot, Gilles, Stichelbaut, Frédéric, De Lentdecker, Gilles, Gerardy, Isabelle, Silari, Marco, Vanhavere, Filip