Cargando…
Commissioning of the Operational Laser Emittance Monitors for LINAC4 at CERN
A laser-based emittance monitor has been developed to non-invasively measure the transverse emittance of the LINAC4 H⁻ beam at its top energy of 160MeV. After testing several sub-systems of the instrument during linac commissioning at intermediate energies, two instruments are now permanently instal...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2018-WEPAL074 http://cds.cern.ch/record/2650969 |