A laser-based emittance monitor has been developed to non-invasively measure the transverse emittance of the LINAC4 H⁻ beam at its top energy of 160MeV. After testing several sub-systems of the instrument during linac commissioning at intermediate energies, two instruments are now permanently instal...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2018-WEPAL074 http://cds.cern.ch/record/2650969 |
Sumario: | A laser-based emittance monitor has been developed to non-invasively measure the transverse emittance of the LINAC4 H⁻ beam at its top energy of 160MeV. After testing several sub-systems of the instrument during linac commissioning at intermediate energies, two instruments are now permanently installed. These instruments use a pulsed laser beam delivered to the accelerator tunnel by optical fibres before final focusing onto the H⁻ beam. The photons in the laser pulse detach electrons from the H⁻ ions, which can then be deflected into an electron multiplier. In addition, the resulting neutral H⁰ atoms can be separated from the main beam by a dipole magnet before being recorded by downstream diamond strip-detectors. By scanning the laser in the horizontal and vertical plane the beam profiles are obtained from the electron signals and the emittance can be reconstructed by the H⁰ profiles at the diamond detectors. This paper describes the final system layout that consists of two independent instruments, each measuring profile and emittance of the H⁻ beam in the horizontal and vertical plane and discusses the preliminary commissioning results. |
---|