Cargando…
Comparing (13)C methyl and deuterated methyl isotopic labeling for the quantification of methyl cellulose patterns using mass spectrometry
The methyl substitution along and among the polymer chains of methyl cellulose (MC) is commonly analyzed by ESI-MS after perdeuteromethylation of the free-OH groups and partial hydrolysis to cello-oligosaccharides (COS). This method requires a correct quantification of the molar ratios of the consti...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10050035/ https://www.ncbi.nlm.nih.gov/pubmed/36867199 http://dx.doi.org/10.1007/s00216-023-04622-w |
Sumario: | The methyl substitution along and among the polymer chains of methyl cellulose (MC) is commonly analyzed by ESI-MS after perdeuteromethylation of the free-OH groups and partial hydrolysis to cello-oligosaccharides (COS). This method requires a correct quantification of the molar ratios of the constituents belonging to a particular degree of polymerization (DP). However, isotopic effects are most pronounced for H/D since their mass difference is 100%. Therefore, we investigated whether more precise and accurate results could be obtained for the methyl distribution of MC by MS of (13)CH(3) instead of CD(3)-etherified O-Me-COS. Internal isotope labeling with (13)CH(3) makes the COS of each DP chemically and physically much more similar, reducing mass fractionation effects, but at the same time requires more complex isotopic correction for evaluation. Results from syringe pump infusion ESI-TOF-MS with (13)CH(3) and CD(3) as isotope label were equal. However, in the case of LC-MS with a gradient system, (13)CH(3) was superior to CD(3). In the case of CD(3), the occurrence of a partial separation of the isotopologs of a particular DP resulted in slight distortion of the methyl distribution since the signal response is significantly dependent on the solvent composition. Isocratic LC levels this problem, but one particular eluent-composition is not sufficient for a series of oligosaccharides with increasing DP due to peak broadening. In summary, (13)CH(3) is more robust to determine the methyl distribution of MCs. Both syringe pump and gradient-LC-MS measurements are possible, and the more complex isotope correction is not a disadvantage. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-023-04622-w. |
---|