Cargando…

Aluminum Nitride Piezoelectric Micromachined Ultrasound Transducer Arrays for Non-Invasive Monitoring of Radial Artery Stiffness

An aluminum nitride (AlN) piezoelectric micromachined ultrasound transducer (PMUT) array was proposed and fabricated for non-invasive radial artery stiffness monitoring, which could be employed in human vascular health monitoring applications. Using surface micromachining techniques, four hexagonal...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Sheng, Liu, Kangfu, Wang, Wenjing, Li, Wei, Wu, Tao, Yang, Heng, Li, Xinxin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10052539/
https://www.ncbi.nlm.nih.gov/pubmed/36984946
http://dx.doi.org/10.3390/mi14030539
_version_ 1785015185377853440
author Wu, Sheng
Liu, Kangfu
Wang, Wenjing
Li, Wei
Wu, Tao
Yang, Heng
Li, Xinxin
author_facet Wu, Sheng
Liu, Kangfu
Wang, Wenjing
Li, Wei
Wu, Tao
Yang, Heng
Li, Xinxin
author_sort Wu, Sheng
collection PubMed
description An aluminum nitride (AlN) piezoelectric micromachined ultrasound transducer (PMUT) array was proposed and fabricated for non-invasive radial artery stiffness monitoring, which could be employed in human vascular health monitoring applications. Using surface micromachining techniques, four hexagonal PMUT arrays were fabricated within a chip area of 3 × 3 mm(2). The mechanical displacement sensitivity and quality factor of a single PMUT were tested and found to be 24.47 nm/V at 5.94 MHz and 278 (in air), respectively. Underwater pulse-echo tests for the array demonstrated a −3 dB bandwidth of 0.76 MHz at 3.75 MHz and distance detection limit of approximately 25 mm. Using the PMUT array as an ultrasonic probe, the depth and diameter changes over cardiac cycles of the radial artery were measured to be approximately 3.8 mm and 0.23 mm, respectively. Combined with blood pressure calibration, the biomechanical parameters of the radial artery vessel were extracted using a one-dimensional vascular model. The cross-sectional distensibility, compliance, and stiffness index were determined to be 4.03 × 10(−3)/mmHg, 1.87 × 10(−2) mm(2)/mmHg, and 5.25, respectively, consistent with the newest medical research. The continuous beat-to-beat blood pressure was also estimated using this model. This work demonstrated the potential of miniaturized PMUT devices for human vascular medical ultrasound applications.
format Online
Article
Text
id pubmed-10052539
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100525392023-03-30 Aluminum Nitride Piezoelectric Micromachined Ultrasound Transducer Arrays for Non-Invasive Monitoring of Radial Artery Stiffness Wu, Sheng Liu, Kangfu Wang, Wenjing Li, Wei Wu, Tao Yang, Heng Li, Xinxin Micromachines (Basel) Article An aluminum nitride (AlN) piezoelectric micromachined ultrasound transducer (PMUT) array was proposed and fabricated for non-invasive radial artery stiffness monitoring, which could be employed in human vascular health monitoring applications. Using surface micromachining techniques, four hexagonal PMUT arrays were fabricated within a chip area of 3 × 3 mm(2). The mechanical displacement sensitivity and quality factor of a single PMUT were tested and found to be 24.47 nm/V at 5.94 MHz and 278 (in air), respectively. Underwater pulse-echo tests for the array demonstrated a −3 dB bandwidth of 0.76 MHz at 3.75 MHz and distance detection limit of approximately 25 mm. Using the PMUT array as an ultrasonic probe, the depth and diameter changes over cardiac cycles of the radial artery were measured to be approximately 3.8 mm and 0.23 mm, respectively. Combined with blood pressure calibration, the biomechanical parameters of the radial artery vessel were extracted using a one-dimensional vascular model. The cross-sectional distensibility, compliance, and stiffness index were determined to be 4.03 × 10(−3)/mmHg, 1.87 × 10(−2) mm(2)/mmHg, and 5.25, respectively, consistent with the newest medical research. The continuous beat-to-beat blood pressure was also estimated using this model. This work demonstrated the potential of miniaturized PMUT devices for human vascular medical ultrasound applications. MDPI 2023-02-25 /pmc/articles/PMC10052539/ /pubmed/36984946 http://dx.doi.org/10.3390/mi14030539 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wu, Sheng
Liu, Kangfu
Wang, Wenjing
Li, Wei
Wu, Tao
Yang, Heng
Li, Xinxin
Aluminum Nitride Piezoelectric Micromachined Ultrasound Transducer Arrays for Non-Invasive Monitoring of Radial Artery Stiffness
title Aluminum Nitride Piezoelectric Micromachined Ultrasound Transducer Arrays for Non-Invasive Monitoring of Radial Artery Stiffness
title_full Aluminum Nitride Piezoelectric Micromachined Ultrasound Transducer Arrays for Non-Invasive Monitoring of Radial Artery Stiffness
title_fullStr Aluminum Nitride Piezoelectric Micromachined Ultrasound Transducer Arrays for Non-Invasive Monitoring of Radial Artery Stiffness
title_full_unstemmed Aluminum Nitride Piezoelectric Micromachined Ultrasound Transducer Arrays for Non-Invasive Monitoring of Radial Artery Stiffness
title_short Aluminum Nitride Piezoelectric Micromachined Ultrasound Transducer Arrays for Non-Invasive Monitoring of Radial Artery Stiffness
title_sort aluminum nitride piezoelectric micromachined ultrasound transducer arrays for non-invasive monitoring of radial artery stiffness
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10052539/
https://www.ncbi.nlm.nih.gov/pubmed/36984946
http://dx.doi.org/10.3390/mi14030539
work_keys_str_mv AT wusheng aluminumnitridepiezoelectricmicromachinedultrasoundtransducerarraysfornoninvasivemonitoringofradialarterystiffness
AT liukangfu aluminumnitridepiezoelectricmicromachinedultrasoundtransducerarraysfornoninvasivemonitoringofradialarterystiffness
AT wangwenjing aluminumnitridepiezoelectricmicromachinedultrasoundtransducerarraysfornoninvasivemonitoringofradialarterystiffness
AT liwei aluminumnitridepiezoelectricmicromachinedultrasoundtransducerarraysfornoninvasivemonitoringofradialarterystiffness
AT wutao aluminumnitridepiezoelectricmicromachinedultrasoundtransducerarraysfornoninvasivemonitoringofradialarterystiffness
AT yangheng aluminumnitridepiezoelectricmicromachinedultrasoundtransducerarraysfornoninvasivemonitoringofradialarterystiffness
AT lixinxin aluminumnitridepiezoelectricmicromachinedultrasoundtransducerarraysfornoninvasivemonitoringofradialarterystiffness