Cargando…

Influence of eight debridement techniques on three different titanium surfaces: A laboratory study

OBJECTIVES: Debridement methods may damage implant surfaces. This in vitro study investigated eight debridement protocols across three implant surfaces to assess both biofilm removal and surface alterations. MATERIAL AND METHODS: One hundred sixty commercially pure titanium discs were treated to sim...

Descripción completa

Detalles Bibliográficos
Autores principales: Tran, Carol, Khan, Ambereen, Meredith, Neil, Walsh, Laurence J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10087144/
https://www.ncbi.nlm.nih.gov/pubmed/35943293
http://dx.doi.org/10.1111/idh.12616