Cargando…

Motion-Based Extrinsic Sensor-to-Sensor Calibration: Effect of Reference Frame Selection for New and Existing Methods

This paper studies the effect of reference frame selection in sensor-to-sensor extrinsic calibration when formulated as a motion-based hand–eye calibration problem. As the sensor trajectories typically contain some composition of noise, the aim is to determine which selection strategies work best un...

Descripción completa

Detalles Bibliográficos
Autores principales: Välimäki, Tuomas, Garigipati, Bharath, Ghabcheloo, Reza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10098754/
https://www.ncbi.nlm.nih.gov/pubmed/37050800
http://dx.doi.org/10.3390/s23073740
_version_ 1785024889691832320
author Välimäki, Tuomas
Garigipati, Bharath
Ghabcheloo, Reza
author_facet Välimäki, Tuomas
Garigipati, Bharath
Ghabcheloo, Reza
author_sort Välimäki, Tuomas
collection PubMed
description This paper studies the effect of reference frame selection in sensor-to-sensor extrinsic calibration when formulated as a motion-based hand–eye calibration problem. As the sensor trajectories typically contain some composition of noise, the aim is to determine which selection strategies work best under which noise conditions. Different reference selection options are tested under varying noise conditions in simulations, and the findings are validated with real data from the KITTI dataset. The study is conducted for four state-of-the-art methods, as well as two proposed cost functions for nonlinear optimization. One of the proposed cost functions incorporates outlier rejection to improve calibration performance and was shown to significantly improve performance in the presence of outliers, and either match or outperform the other algorithms in other noise conditions. However, the performance gain from reference frame selection was deemed larger than that from algorithm selection. In addition, we show that with realistic noise, the reference frame selection method commonly used in the literature, is inferior to other tested options, and that relative error metrics are not reliable for telling which method achieves best calibration performance.
format Online
Article
Text
id pubmed-10098754
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100987542023-04-14 Motion-Based Extrinsic Sensor-to-Sensor Calibration: Effect of Reference Frame Selection for New and Existing Methods Välimäki, Tuomas Garigipati, Bharath Ghabcheloo, Reza Sensors (Basel) Article This paper studies the effect of reference frame selection in sensor-to-sensor extrinsic calibration when formulated as a motion-based hand–eye calibration problem. As the sensor trajectories typically contain some composition of noise, the aim is to determine which selection strategies work best under which noise conditions. Different reference selection options are tested under varying noise conditions in simulations, and the findings are validated with real data from the KITTI dataset. The study is conducted for four state-of-the-art methods, as well as two proposed cost functions for nonlinear optimization. One of the proposed cost functions incorporates outlier rejection to improve calibration performance and was shown to significantly improve performance in the presence of outliers, and either match or outperform the other algorithms in other noise conditions. However, the performance gain from reference frame selection was deemed larger than that from algorithm selection. In addition, we show that with realistic noise, the reference frame selection method commonly used in the literature, is inferior to other tested options, and that relative error metrics are not reliable for telling which method achieves best calibration performance. MDPI 2023-04-04 /pmc/articles/PMC10098754/ /pubmed/37050800 http://dx.doi.org/10.3390/s23073740 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Välimäki, Tuomas
Garigipati, Bharath
Ghabcheloo, Reza
Motion-Based Extrinsic Sensor-to-Sensor Calibration: Effect of Reference Frame Selection for New and Existing Methods
title Motion-Based Extrinsic Sensor-to-Sensor Calibration: Effect of Reference Frame Selection for New and Existing Methods
title_full Motion-Based Extrinsic Sensor-to-Sensor Calibration: Effect of Reference Frame Selection for New and Existing Methods
title_fullStr Motion-Based Extrinsic Sensor-to-Sensor Calibration: Effect of Reference Frame Selection for New and Existing Methods
title_full_unstemmed Motion-Based Extrinsic Sensor-to-Sensor Calibration: Effect of Reference Frame Selection for New and Existing Methods
title_short Motion-Based Extrinsic Sensor-to-Sensor Calibration: Effect of Reference Frame Selection for New and Existing Methods
title_sort motion-based extrinsic sensor-to-sensor calibration: effect of reference frame selection for new and existing methods
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10098754/
https://www.ncbi.nlm.nih.gov/pubmed/37050800
http://dx.doi.org/10.3390/s23073740
work_keys_str_mv AT valimakituomas motionbasedextrinsicsensortosensorcalibrationeffectofreferenceframeselectionfornewandexistingmethods
AT garigipatibharath motionbasedextrinsicsensortosensorcalibrationeffectofreferenceframeselectionfornewandexistingmethods
AT ghabchelooreza motionbasedextrinsicsensortosensorcalibrationeffectofreferenceframeselectionfornewandexistingmethods