Cargando…

A multiple regression based method for indirect compensation of hemispherical resonator gyro temperature error

In order to improve the measuring accuracy of the Hemispherical Resonator Gyro under variable temperature, aiming at the problem of "external temperature is unavailable and internal temperature is unmeasurable," a multiple regression based method is proposed for compensating temperature er...

Descripción completa

Detalles Bibliográficos
Autores principales: Xin-san, Li, Can, Li, Qiang, Shen, Li-xin, Wang, Shuan-zhu, Li
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10101989/
https://www.ncbi.nlm.nih.gov/pubmed/37055430
http://dx.doi.org/10.1038/s41598-023-31868-2