Cargando…

Voltage sensor current, SR Ca(2+) release, and Ca(2+) channel current during trains of action potential‐like depolarizations of skeletal muscle fibers

In skeletal muscle, Ca( V )1.1 serves as the voltage sensor for both excitation‐contraction coupling (ECC) and L‐type Ca(2+) channel activation. We have recently adapted the technique of action potential (AP) voltage clamp (APVC) to monitor the current generated by the movement of intramembrane volt...

Descripción completa

Detalles Bibliográficos
Autores principales: Bibollet, Hugo, Nguyen, Elton L., Miranda, Daniel R., Ward, Christopher W., Voss, Andrew A., Schneider, Martin F., Hernández‐Ochoa, Erick O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10163276/
https://www.ncbi.nlm.nih.gov/pubmed/37147904