Silicone ring tourniquet could be a substitute for a conventional tourniquet in total knee arthroplasty with a longer surgical field: a prospective comparative study in simultaneous total knee arthroplasty
INTRODUCTION: This study aimed to compare the clinical outcomes of silicon ring tourniquets and conventional pneumatic tourniquets in total knee arthroplasty (TKA). The study compared the operation time, total bleeding amount, length from the tourniquet distal end to the patella superior pole (L_TP)...