Temperature resistant anti-reflective coating on Si-wafer for long-wave infra-red imaging

A micromachined Silicon lid, sealed by CuSn solid liquid interdiffusion bonding is a promising approach for hermetic sealing of microbolometers for use in low-cost thermal cameras. However, since ∼30% of long-wave infrared light is reflected at an uncoated single Si-air interface, anti-reflective tr...

Descripción completa

Detalles Bibliográficos
Autores principales: Papatzacos, Phillip H., Akram, M. Nadeem, Hector, Olivier, Lemarquis, Frédéric, Moreau, Antonin, Lumeau, Julien, Ohlckers, Per
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10172777/
https://www.ncbi.nlm.nih.gov/pubmed/37180893
http://dx.doi.org/10.1016/j.heliyon.2023.e15888
_version_ 1785039686318686208
author Papatzacos, Phillip H.
Akram, M. Nadeem
Hector, Olivier
Lemarquis, Frédéric
Moreau, Antonin
Lumeau, Julien
Ohlckers, Per
author_facet Papatzacos, Phillip H.
Akram, M. Nadeem
Hector, Olivier
Lemarquis, Frédéric
Moreau, Antonin
Lumeau, Julien
Ohlckers, Per
author_sort Papatzacos, Phillip H.
collection PubMed
description A micromachined Silicon lid, sealed by CuSn solid liquid interdiffusion bonding is a promising approach for hermetic sealing of microbolometers for use in low-cost thermal cameras. However, since ∼30% of long-wave infrared light is reflected at an uncoated single Si-air interface, anti-reflective treatments are required. Traditional anti-reflective coatings are inapplicable since CuSn solid liquid interdiffusion bonding requires heating to about 270 °C and these multi-layer coatings fail due to differing coefficients of thermal expansion for the different layers and the substrate. For this purpose, an anti-reflective coating that maintains its anti-reflective properties after being heat-cycled to 300 °C has been developed. This coating was developed using a simple 2-layer structure composed of ZnS and YF(3) and deposited at 100 °C. The development process that led to the successful coating has also been described in this paper. The final sample shows a 30% average increase in transmission in the 8–12 μm wavelength range as compared to an uncoated wafer.
format Online
Article
Text
id pubmed-10172777
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-101727772023-05-12 Temperature resistant anti-reflective coating on Si-wafer for long-wave infra-red imaging Papatzacos, Phillip H. Akram, M. Nadeem Hector, Olivier Lemarquis, Frédéric Moreau, Antonin Lumeau, Julien Ohlckers, Per Heliyon Research Article A micromachined Silicon lid, sealed by CuSn solid liquid interdiffusion bonding is a promising approach for hermetic sealing of microbolometers for use in low-cost thermal cameras. However, since ∼30% of long-wave infrared light is reflected at an uncoated single Si-air interface, anti-reflective treatments are required. Traditional anti-reflective coatings are inapplicable since CuSn solid liquid interdiffusion bonding requires heating to about 270 °C and these multi-layer coatings fail due to differing coefficients of thermal expansion for the different layers and the substrate. For this purpose, an anti-reflective coating that maintains its anti-reflective properties after being heat-cycled to 300 °C has been developed. This coating was developed using a simple 2-layer structure composed of ZnS and YF(3) and deposited at 100 °C. The development process that led to the successful coating has also been described in this paper. The final sample shows a 30% average increase in transmission in the 8–12 μm wavelength range as compared to an uncoated wafer. Elsevier 2023-04-27 /pmc/articles/PMC10172777/ /pubmed/37180893 http://dx.doi.org/10.1016/j.heliyon.2023.e15888 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Papatzacos, Phillip H.
Akram, M. Nadeem
Hector, Olivier
Lemarquis, Frédéric
Moreau, Antonin
Lumeau, Julien
Ohlckers, Per
Temperature resistant anti-reflective coating on Si-wafer for long-wave infra-red imaging
title Temperature resistant anti-reflective coating on Si-wafer for long-wave infra-red imaging
title_full Temperature resistant anti-reflective coating on Si-wafer for long-wave infra-red imaging
title_fullStr Temperature resistant anti-reflective coating on Si-wafer for long-wave infra-red imaging
title_full_unstemmed Temperature resistant anti-reflective coating on Si-wafer for long-wave infra-red imaging
title_short Temperature resistant anti-reflective coating on Si-wafer for long-wave infra-red imaging
title_sort temperature resistant anti-reflective coating on si-wafer for long-wave infra-red imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10172777/
https://www.ncbi.nlm.nih.gov/pubmed/37180893
http://dx.doi.org/10.1016/j.heliyon.2023.e15888
work_keys_str_mv AT papatzacosphilliph temperatureresistantantireflectivecoatingonsiwaferforlongwaveinfraredimaging
AT akrammnadeem temperatureresistantantireflectivecoatingonsiwaferforlongwaveinfraredimaging
AT hectorolivier temperatureresistantantireflectivecoatingonsiwaferforlongwaveinfraredimaging
AT lemarquisfrederic temperatureresistantantireflectivecoatingonsiwaferforlongwaveinfraredimaging
AT moreauantonin temperatureresistantantireflectivecoatingonsiwaferforlongwaveinfraredimaging
AT lumeaujulien temperatureresistantantireflectivecoatingonsiwaferforlongwaveinfraredimaging
AT ohlckersper temperatureresistantantireflectivecoatingonsiwaferforlongwaveinfraredimaging