Porous Biocoatings Based on Diatomite with Incorporated ZrO(2) Particles for Biodegradable Magnesium Implants

In the present work, the surface of a biodegradable Mg alloy was modified to create porous diatomite biocoatings using the method of micro-arc oxidation. The coatings were applied at process voltages in the range of 350–500 V. We have studied the influence of the addition of ZrO(2) microparticles on...