Cargando…

An In Silico Approach toward the Appropriate Absorption Rate Metric in Bioequivalence

In bioequivalence, the maximum plasma concentration (Cmax) is traditionally used as a metric for the absorption rate, despite the fact that there are several concerns. The idea of “average slope” (AS) was recently introduced as an alternative metric to reflect absorption rate. This study aims to fur...

Descripción completa

Detalles Bibliográficos
Autor principal: Karalis, Vangelis D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221334/
https://www.ncbi.nlm.nih.gov/pubmed/37242508
http://dx.doi.org/10.3390/ph16050725
_version_ 1785049431271276544
author Karalis, Vangelis D.
author_facet Karalis, Vangelis D.
author_sort Karalis, Vangelis D.
collection PubMed
description In bioequivalence, the maximum plasma concentration (Cmax) is traditionally used as a metric for the absorption rate, despite the fact that there are several concerns. The idea of “average slope” (AS) was recently introduced as an alternative metric to reflect absorption rate. This study aims to further extend the previous findings and apply an in silico approach to investigate the kinetic sensitivity of AS and Cmax. This computational analysis was applied to the C-t data of hydrochlorothiazide, donepezil, and amlodipine, which exhibit different absorption kinetics. Principal component analysis (PCA) was applied to uncover the relationships between all bioequivalence metrics. Monte Carlo simulations of bioequivalence trials were performed to investigate sensitivity. The appropriate programming codes were written in Python for the PCA and in MATLAB(®) for the simulations. The PCA verified the desired properties of AS and the unsuitability of Cmax to reflect absorption rate. The Monte Carlo simulations showed that AS is quite sensitive to detecting differences in absorption rate, while Cmax has almost negligible sensitivity. Cmax fails to reflect absorption rate, and its use in bioequivalence gives only a false impression. AS has the appropriate units, is easily calculated, exhibits high sensitivity, and has the desired properties of absorption rate.
format Online
Article
Text
id pubmed-10221334
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102213342023-05-28 An In Silico Approach toward the Appropriate Absorption Rate Metric in Bioequivalence Karalis, Vangelis D. Pharmaceuticals (Basel) Article In bioequivalence, the maximum plasma concentration (Cmax) is traditionally used as a metric for the absorption rate, despite the fact that there are several concerns. The idea of “average slope” (AS) was recently introduced as an alternative metric to reflect absorption rate. This study aims to further extend the previous findings and apply an in silico approach to investigate the kinetic sensitivity of AS and Cmax. This computational analysis was applied to the C-t data of hydrochlorothiazide, donepezil, and amlodipine, which exhibit different absorption kinetics. Principal component analysis (PCA) was applied to uncover the relationships between all bioequivalence metrics. Monte Carlo simulations of bioequivalence trials were performed to investigate sensitivity. The appropriate programming codes were written in Python for the PCA and in MATLAB(®) for the simulations. The PCA verified the desired properties of AS and the unsuitability of Cmax to reflect absorption rate. The Monte Carlo simulations showed that AS is quite sensitive to detecting differences in absorption rate, while Cmax has almost negligible sensitivity. Cmax fails to reflect absorption rate, and its use in bioequivalence gives only a false impression. AS has the appropriate units, is easily calculated, exhibits high sensitivity, and has the desired properties of absorption rate. MDPI 2023-05-10 /pmc/articles/PMC10221334/ /pubmed/37242508 http://dx.doi.org/10.3390/ph16050725 Text en © 2023 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Karalis, Vangelis D.
An In Silico Approach toward the Appropriate Absorption Rate Metric in Bioequivalence
title An In Silico Approach toward the Appropriate Absorption Rate Metric in Bioequivalence
title_full An In Silico Approach toward the Appropriate Absorption Rate Metric in Bioequivalence
title_fullStr An In Silico Approach toward the Appropriate Absorption Rate Metric in Bioequivalence
title_full_unstemmed An In Silico Approach toward the Appropriate Absorption Rate Metric in Bioequivalence
title_short An In Silico Approach toward the Appropriate Absorption Rate Metric in Bioequivalence
title_sort in silico approach toward the appropriate absorption rate metric in bioequivalence
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221334/
https://www.ncbi.nlm.nih.gov/pubmed/37242508
http://dx.doi.org/10.3390/ph16050725
work_keys_str_mv AT karalisvangelisd aninsilicoapproachtowardtheappropriateabsorptionratemetricinbioequivalence
AT karalisvangelisd insilicoapproachtowardtheappropriateabsorptionratemetricinbioequivalence