Cargando…

Advancements in a FRET Biosensor for Live-Cell Fluorescence-Lifetime High-Throughput Screening of Alpha-Synuclein

There is a critical need for small molecules capable of rescuing pathophysiological phenotypes induced by alpha-synuclein (aSyn) misfolding and oligomerization. Building upon our previous aSyn cellular fluorescence lifetime (FLT)-Förster resonance energy transfer (FRET) biosensors, we have developed...

Descripción completa

Detalles Bibliográficos
Autores principales: Braun, Anthony R., Kochen, Noah Nathan, Yuen, Samantha L., Liao, Elly E., Cornea, Razvan L., Thomas, David D., Sachs, Jonathan N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10338669/
https://www.ncbi.nlm.nih.gov/pubmed/37428128
http://dx.doi.org/10.1177/17590914231184086
_version_ 1785071675609448448
author Braun, Anthony R.
Kochen, Noah Nathan
Yuen, Samantha L.
Liao, Elly E.
Cornea, Razvan L.
Thomas, David D.
Sachs, Jonathan N.
author_facet Braun, Anthony R.
Kochen, Noah Nathan
Yuen, Samantha L.
Liao, Elly E.
Cornea, Razvan L.
Thomas, David D.
Sachs, Jonathan N.
author_sort Braun, Anthony R.
collection PubMed
description There is a critical need for small molecules capable of rescuing pathophysiological phenotypes induced by alpha-synuclein (aSyn) misfolding and oligomerization. Building upon our previous aSyn cellular fluorescence lifetime (FLT)-Förster resonance energy transfer (FRET) biosensors, we have developed an inducible cell model incorporating the red-shifted mCyRFP1/mMaroon1 (OFP/MFP) FRET pair. This new aSyn FRET biosensor improves the signal-to-noise ratio, reduces nonspecific background FRET, and results in a 4-fold increase (transient transfection) and 2-fold increase (stable, inducible cell lines) in FRET signal relative to our previous GFP/RFP aSyn biosensors. The inducible system institutes greater temporal control and scalability, allowing for fine-tuning of biosensor expression and minimizes cellular cytotoxicity due to overexpression of aSyn. Using these inducible aSyn-OFP/MFP biosensors, we screened the Selleck library of 2684 commercially available, FDA-approved compounds and identified proanthocyanidins and casanthranol as novel hits. Secondary assays validated the ability of these compounds to modulate aSyn FLT-FRET. Functional assays probing cellular cytotoxicity and aSyn fibrillization demonstrated their capability to inhibit seeded aSyn fibrillization. Proanthocyanidins completely rescued aSyn fibril-induced cellular toxicity with EC(50) of 200 nM and casanthranol supported a 85.5% rescue with a projected EC(50) of 34.2 μM. Furthermore, proanthocyanidins provide a valuable tool compound to validate our aSyn biosensor performance in future high-throughput screening campaigns of industrial-scale (million-compound) chemical libraries.
format Online
Article
Text
id pubmed-10338669
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-103386692023-07-14 Advancements in a FRET Biosensor for Live-Cell Fluorescence-Lifetime High-Throughput Screening of Alpha-Synuclein Braun, Anthony R. Kochen, Noah Nathan Yuen, Samantha L. Liao, Elly E. Cornea, Razvan L. Thomas, David D. Sachs, Jonathan N. ASN Neuro Original Papers There is a critical need for small molecules capable of rescuing pathophysiological phenotypes induced by alpha-synuclein (aSyn) misfolding and oligomerization. Building upon our previous aSyn cellular fluorescence lifetime (FLT)-Förster resonance energy transfer (FRET) biosensors, we have developed an inducible cell model incorporating the red-shifted mCyRFP1/mMaroon1 (OFP/MFP) FRET pair. This new aSyn FRET biosensor improves the signal-to-noise ratio, reduces nonspecific background FRET, and results in a 4-fold increase (transient transfection) and 2-fold increase (stable, inducible cell lines) in FRET signal relative to our previous GFP/RFP aSyn biosensors. The inducible system institutes greater temporal control and scalability, allowing for fine-tuning of biosensor expression and minimizes cellular cytotoxicity due to overexpression of aSyn. Using these inducible aSyn-OFP/MFP biosensors, we screened the Selleck library of 2684 commercially available, FDA-approved compounds and identified proanthocyanidins and casanthranol as novel hits. Secondary assays validated the ability of these compounds to modulate aSyn FLT-FRET. Functional assays probing cellular cytotoxicity and aSyn fibrillization demonstrated their capability to inhibit seeded aSyn fibrillization. Proanthocyanidins completely rescued aSyn fibril-induced cellular toxicity with EC(50) of 200 nM and casanthranol supported a 85.5% rescue with a projected EC(50) of 34.2 μM. Furthermore, proanthocyanidins provide a valuable tool compound to validate our aSyn biosensor performance in future high-throughput screening campaigns of industrial-scale (million-compound) chemical libraries. SAGE Publications 2023-07-10 /pmc/articles/PMC10338669/ /pubmed/37428128 http://dx.doi.org/10.1177/17590914231184086 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Papers
Braun, Anthony R.
Kochen, Noah Nathan
Yuen, Samantha L.
Liao, Elly E.
Cornea, Razvan L.
Thomas, David D.
Sachs, Jonathan N.
Advancements in a FRET Biosensor for Live-Cell Fluorescence-Lifetime High-Throughput Screening of Alpha-Synuclein
title Advancements in a FRET Biosensor for Live-Cell Fluorescence-Lifetime High-Throughput Screening of Alpha-Synuclein
title_full Advancements in a FRET Biosensor for Live-Cell Fluorescence-Lifetime High-Throughput Screening of Alpha-Synuclein
title_fullStr Advancements in a FRET Biosensor for Live-Cell Fluorescence-Lifetime High-Throughput Screening of Alpha-Synuclein
title_full_unstemmed Advancements in a FRET Biosensor for Live-Cell Fluorescence-Lifetime High-Throughput Screening of Alpha-Synuclein
title_short Advancements in a FRET Biosensor for Live-Cell Fluorescence-Lifetime High-Throughput Screening of Alpha-Synuclein
title_sort advancements in a fret biosensor for live-cell fluorescence-lifetime high-throughput screening of alpha-synuclein
topic Original Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10338669/
https://www.ncbi.nlm.nih.gov/pubmed/37428128
http://dx.doi.org/10.1177/17590914231184086
work_keys_str_mv AT braunanthonyr advancementsinafretbiosensorforlivecellfluorescencelifetimehighthroughputscreeningofalphasynuclein
AT kochennoahnathan advancementsinafretbiosensorforlivecellfluorescencelifetimehighthroughputscreeningofalphasynuclein
AT yuensamanthal advancementsinafretbiosensorforlivecellfluorescencelifetimehighthroughputscreeningofalphasynuclein
AT liaoellye advancementsinafretbiosensorforlivecellfluorescencelifetimehighthroughputscreeningofalphasynuclein
AT cornearazvanl advancementsinafretbiosensorforlivecellfluorescencelifetimehighthroughputscreeningofalphasynuclein
AT thomasdavidd advancementsinafretbiosensorforlivecellfluorescencelifetimehighthroughputscreeningofalphasynuclein
AT sachsjonathann advancementsinafretbiosensorforlivecellfluorescencelifetimehighthroughputscreeningofalphasynuclein