Using a 3D Navigation Template to Increase the Accuracy of Thoracic Pedicle Screws in Patients with Scoliosis
This study compares the accuracy and safety of pedicle screw placement using a 3D navigation template with the free-hand fluoroscopy technique in scoliotic patients. Fifteen scoliotic patients were recruited and divided into a template group (eight cases) and a free-hand group (seven cases). All pat...