Fabrication and Characterization of Three-Dimensional Microelectromechanical System Coaxial Socket Device for Semiconductor Package Testing

With the continuous reduction in size and increase in density of semiconductor devices, there is a growing demand for contact solutions that enable high-speed testing in automotive, 5G, and artificial intelligence-based devices. Although existing solutions, such as spring pins and rubber sockets, ha...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Tae-Kyun, Yook, Jong-Gwan, Kim, Joo-Yong, Cho, Yong-Ho, Lee, Uh-Hyeon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10386342/
https://www.ncbi.nlm.nih.gov/pubmed/37514644
http://dx.doi.org/10.3390/s23146350
_version_ 1785081640692744192
author Kim, Tae-Kyun
Yook, Jong-Gwan
Kim, Joo-Yong
Cho, Yong-Ho
Lee, Uh-Hyeon
author_facet Kim, Tae-Kyun
Yook, Jong-Gwan
Kim, Joo-Yong
Cho, Yong-Ho
Lee, Uh-Hyeon
author_sort Kim, Tae-Kyun
collection PubMed
description With the continuous reduction in size and increase in density of semiconductor devices, there is a growing demand for contact solutions that enable high-speed testing in automotive, 5G, and artificial intelligence-based devices. Although existing solutions, such as spring pins and rubber sockets, have been effective in various applications, there is still a need for new solutions that accommodate fine-pitch, high-speed, and high-density requirements. This study proposes a novel three-dimensional microelectromechanical system spring structure coaxial socket for semiconductor chip package testing. The socket design incorporates impedance matching for high-speed testing and addresses the challenges of fine-pitch and high-density applications. Mechanical tests are conducted to evaluate the durability of the structure and electrical tests are performed to verify electrical characteristics by utilizing a vector network analyzer up to 60 GHz. Our results have revealed promising performance and will help in further optimizing the design for potential production in the field and industry.
format Online
Article
Text
id pubmed-10386342
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103863422023-07-30 Fabrication and Characterization of Three-Dimensional Microelectromechanical System Coaxial Socket Device for Semiconductor Package Testing Kim, Tae-Kyun Yook, Jong-Gwan Kim, Joo-Yong Cho, Yong-Ho Lee, Uh-Hyeon Sensors (Basel) Article With the continuous reduction in size and increase in density of semiconductor devices, there is a growing demand for contact solutions that enable high-speed testing in automotive, 5G, and artificial intelligence-based devices. Although existing solutions, such as spring pins and rubber sockets, have been effective in various applications, there is still a need for new solutions that accommodate fine-pitch, high-speed, and high-density requirements. This study proposes a novel three-dimensional microelectromechanical system spring structure coaxial socket for semiconductor chip package testing. The socket design incorporates impedance matching for high-speed testing and addresses the challenges of fine-pitch and high-density applications. Mechanical tests are conducted to evaluate the durability of the structure and electrical tests are performed to verify electrical characteristics by utilizing a vector network analyzer up to 60 GHz. Our results have revealed promising performance and will help in further optimizing the design for potential production in the field and industry. MDPI 2023-07-12 /pmc/articles/PMC10386342/ /pubmed/37514644 http://dx.doi.org/10.3390/s23146350 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Tae-Kyun
Yook, Jong-Gwan
Kim, Joo-Yong
Cho, Yong-Ho
Lee, Uh-Hyeon
Fabrication and Characterization of Three-Dimensional Microelectromechanical System Coaxial Socket Device for Semiconductor Package Testing
title Fabrication and Characterization of Three-Dimensional Microelectromechanical System Coaxial Socket Device for Semiconductor Package Testing
title_full Fabrication and Characterization of Three-Dimensional Microelectromechanical System Coaxial Socket Device for Semiconductor Package Testing
title_fullStr Fabrication and Characterization of Three-Dimensional Microelectromechanical System Coaxial Socket Device for Semiconductor Package Testing
title_full_unstemmed Fabrication and Characterization of Three-Dimensional Microelectromechanical System Coaxial Socket Device for Semiconductor Package Testing
title_short Fabrication and Characterization of Three-Dimensional Microelectromechanical System Coaxial Socket Device for Semiconductor Package Testing
title_sort fabrication and characterization of three-dimensional microelectromechanical system coaxial socket device for semiconductor package testing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10386342/
https://www.ncbi.nlm.nih.gov/pubmed/37514644
http://dx.doi.org/10.3390/s23146350
work_keys_str_mv AT kimtaekyun fabricationandcharacterizationofthreedimensionalmicroelectromechanicalsystemcoaxialsocketdeviceforsemiconductorpackagetesting
AT yookjonggwan fabricationandcharacterizationofthreedimensionalmicroelectromechanicalsystemcoaxialsocketdeviceforsemiconductorpackagetesting
AT kimjooyong fabricationandcharacterizationofthreedimensionalmicroelectromechanicalsystemcoaxialsocketdeviceforsemiconductorpackagetesting
AT choyongho fabricationandcharacterizationofthreedimensionalmicroelectromechanicalsystemcoaxialsocketdeviceforsemiconductorpackagetesting
AT leeuhhyeon fabricationandcharacterizationofthreedimensionalmicroelectromechanicalsystemcoaxialsocketdeviceforsemiconductorpackagetesting